DC−bus operation

Fuses and cable cross−sections

DC supply

12

l

471

EDS82EV903−3.0

Inverter

DC fuse 14 × 51

(EFSGR0xx0AYHx)

DC fuse 22 × 58

(EFSGR0xx0AYIx)

Installation in

accordance with

EN 60204−1

Type

Mains

Rated current of fuse

Rated current of fuse

+U

G

, −U

G

Laying system

B2

C

[A]

[A]

[mm

2

]

[mm

2

]

E82xV551K4C

3/PE

400 V

12

12

1.5

1.5

E82xV751K4C

12

12

1.5

1.5

E82xV152K4C

12

12

1.5

1.5

E82xV222K4C

20

20

1.5

1.5

E82xV302K4C

20

20

2.5

2.5

E82xV402K4C

32

32

2.5

2.5

E82xV552K4C

40

40

4.0

4.0

E82xV752K4C

40

40

6.0

1)

4.0

1)

E82xV113K4C

50

50

6.0

1)

4.0

1)

1)

Pin−end connector required, since a maximum cable cross−section of 4 mm

2

can be connected to the inverter.

Inverter

DC fuse NH1

(EFSGRxxx0ANVx)

DC fuse 22 × 58

(EFSGR0xx0AYIx)

Installation in

accordance with

EN 60204−1

Type

Mains

Rated current of fuse

Rated current of fuse

+U

G

, −U

G

Laying system

B2

C

[A]

[A]

[mm

2

]

[mm

2

]

E82xV153K4B

3/PE

400 V

100

100

25

E82xV223K4B

100

100

25

E82xV303K4B

200

25

E82xV453K4B

200

50

Inverter

DC fuse NH2

(EFSGRxxx0ANWx)

DC fuse 22 × 58

(EFSGR0xx0AYIx)

Installation in

accordance with

EN 60204−1

Type

Mains

Rated fuse current

Rated fuse current

+U

G

, −U

G

Laying system

F

C

[A]

[A]

[mm

2

]

[mm

2

]

E82xV553K4B

3/PE

400 V

250

95

E82xV753K4B

350

95

E82xV903K4B

350

95