Function library

Code table

10

l

400

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0174
*

s

Switching
threshold −
brake chopper

100

78

{1 %}

110 Only active with 8200 motec 3 ...

7.5 kW and 8200 vector
0.55 ... 11 kW, version for
400/500 V mains voltage

l

100 % = switching threshold
DC 790 V

l

110 % = brake chopper
switched off

l

U

DC

= switching threshold in V

DC

l

The recommended setting
considers max. 10 % mains
overvoltage

^ 484

Required setting

U

mains

[3/PE AC xxx V]

380
400
415
440
460
480
500

C0174

[%]

78
81
84
89
93
97

100

U

DC

[V DC]

618
642
665
704
735
767
790

C0178
*

Operating
hours

{h}

Read only
Total time − terminal 28 (CINH) =
HIGH

C0179
*

Power−on time

{h}

Read only
Total time of mains "ON"

C0181
*

Process
controller
setpoint 2
(PCTRL1−SET2)

0.00

−650.00

{0.02

Hz}

650.00

^ 322

C0182
*

Integration
time − S−ramps

0.00

0.00

{0.01 s}

50.00

l

C0182 = 0.00: ramp function
generator operates linearly

l

C0182 > 0.00: ramp function
generator operates in an
S−shape (without jerk)

^ 286

C0183
*

Diagnostics

0

No fault

Read only

102

TRIP active

104

Message "Overvoltage (OU)" or
"Undervoltage (LU)" active

142

Pulse inhibit

151

Quick stop is active

161

DC injection brake active

250

Warning active

C0184
*

Frequency
threshold
PCTRL1−I−OFF

0.0

0.0

{0.1 Hz}

25.0

l

If output frequency < C0184,
the I component of the process
controller is switched off

l

0.0 Hz = function inactive

^ 322

C0185
*

Switching
window for
"Frequency
setpoint
reached
(C0415/x = 4)"
and "NSET1−
RFG1−I=O
(C0415/x = 5)"

0

0

{1 %}

80

l

C0415/x = 4 and C0415/x = 5
are active within a window
which opens up around
NSET1−RFG1−IN

l

Window if C0185 = 0%:
± 0.5 % based on C0011

l

Window if C0185 > 0%:
± C0185 based on
NSET1−RFG1−IN

C0189
*
(A)

Output signal −
follow−up
controller
(PCTRL1−FOLL1−
OUT)

−650.00

{0.02

Hz}

650.00 Read only

Follow−up controller =
PCTRL1−FOLL1

Advertising