Standard devices in a power range from 0.25 ... 2.2 kW
Fuses and cable cross−sections according to UL

6

l

128

EDS82EV903 EN 3.0

Operation at rated power

8200 vector

Rated fuse current / cable cross−section

Fuse

Circuit−breaker

Type

L1, L2, L3, N, PE

Type

L1, L2, L3, N, PE

Type

[A]

[AWG]

[A]

[AWG]

Mains 1/N/PE AC 230/240 V − operation without mains choke/mains filter

E82xV251K2C

10

16

15

14

4)

E82xV371K2C

10

16

15

14

4)

E82xV551K2C

10

16

15

14

4)

E82xV751K2C

15

14

15

14

4)

E82xV152K2C

20

2 x 16

25

2 x 14

4)

E82xV222K2C

20

2 x 16

30

2 x 14

4)

Mains 1/N/PE AC 230/240 V − operation with mains choke/mains filter

E82xV251K2C

10

16

15

14

4)

E82xV371K2C

10

16

15

14

4)

E82xV551K2C

10

16

15

14

4)

E82xV751K2C

15

14

15

14

4)

E82xV152K2C

20

2 x 16

25

2 x 14

4)

E82xV222K2C

20

2 x 16

30

2 x 14

4)

Mains 3/PE AC 230/240 V − operation without mains choke/mains filter

E82xV551K2C

6

18

15

14

4)

E82xV751K2C

10

16

15

14

4)

E82xV152K2C

15

14

15

14

4)

E82xV222K2C

15

2 x 16

20

2 x 14

4)

Mains 3/PE AC 230/240 V − operation with mains choke/mains filter

E82xV551K2C

6

18

15

14

4)

E82xV751K2C

10

16

15

14

4)

E82xV152K2C

15

14

15

14

4)

E82xV222K2C

15

2 x 16

20

2 x 14

4)

Mains 3/PE AC 400/500 V − operation without mains choke/mains filter

E82xV551K4C

6

18

15

14

4)

E82xV751K4C

6

18

15

14

4)

E82xV152K4C

10

16

15

14

4)

E82xV222K4C

10

16

15

14

4)

Mains 3/PE AC 400/500 V − operation with mains choke/mains filter

E82xV551K4C

6

18

15

14

4)

E82xV751K4C

6

18

15

14

4)

E82xV152K4C

10

16

15

14

4)

E82xV222K4C

10

16

15

14

4)

4)