DC−bus operation

Central supply (one supply point)

Central supply 400 V with regenerative power supply unit 934X

12

l

479

EDS82EV903−3.0

12.7.2

Central supply 400 V with regenerative power supply unit 934X

Basic circuit diagram

K1

K1

L3

N

PE

L1

L2

U

V

W

M

3~

L1

L2

L3

+UG

-UG

J

mot1

X1

K1

F4

ON

OFF

U

V

W

M

3~

L1

L2

L3

+UG

-UG

X2

F5

A1

A2

Z3

L1

L2

L3

F1

+UG

-UG

Z1

F4

F2 F3

F5

J

mot2

M

3~

F4

F5

+

+

+

+

+

+

+

+

+

8200vec655

Fig. 12−4

Network of 400 V controllers with central supply via 934X regenerative power supply unit

A1, A2

400 V controller of the 8200 vector or 9300 series

Z1

Mains filter(

465)

Z3

934x regenerative power supply module

F1 ... F3

Mains fuses (

467)

F4 ... F5

Fuses on DC level (

470)

K1

Main contactor