Dc−bus operation – Lenze E82xVxxxKxxxxx User Manual
Page 479
Advertising
![background image](/manuals/566070/479/background.png)
DC−bus operation
Central supply (one supply point)
Central supply 400 V with regenerative power supply unit 934X
l
479
EDS82EV903−3.0
12.7.2
Central supply 400 V with regenerative power supply unit 934X
Basic circuit diagram
K1
K1
L3
N
PE
L1
L2
U
V
W
M
3~
L1
L2
L3
+UG
-UG
J
mot1
X1
K1
F4
ON
OFF
U
V
W
M
3~
L1
L2
L3
+UG
-UG
X2
F5
A1
A2
Z3
L1
L2
L3
F1
+UG
-UG
Z1
F4
F2 F3
F5
J
mot2
M
3~
F4
F5
+
+
+
+
+
+
+
+
+
8200vec655
Fig. 12−4
Network of 400 V controllers with central supply via 934X regenerative power supply unit
A1, A2
400 V controller of the 8200 vector or 9300 series
Z1
Mains filter(
¶ 465)
Z3
934x regenerative power supply module
F1 ... F3
Mains fuses (
¶ 467)
F4 ... F5
Fuses on DC level (
¶ 470)
K1
Main contactor
Advertising