Function library

Code table

10

l

389

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0047
*

Torque
setpoint or
torque limit
(MCTRL1−
MSET)

400

0

{1 %}

400 The set value will be lost during

mains switching!

^ 264

Reference: Rated motor torque determined
through motor parameter identification

In "Sensorless torque control"
operating mode (C0014 = 5):

l

Torque setpoint selection if
C0412/6 = FIXED−FREE (not
assigned)

l

Torque setpoint display if
C0412/6 is linked to a signal
source

In "V/f characteristic control" or
"Vector control" operating mode
(C0014 = 2, 3, 4):

l

Display of the torque limit
value if C0412/6 is linked to a
signal source

l

Display C0047 = 400 if
C0412/6 = FIXED−FREE (not
assigned)

C0049
*

Additional
setpoint
(PCTRL1−NADD)

−650.00

{0.02

Hz}

650.00 The set value will be lost during

mains switching!

l

Selection if C0412/3 =
FIXED−FREE (not assigned)

l

Display if C0412/3 is linked to
a signal source

C0050
*

uSEr

Output
frequency
(MCTRL1−
NOUT)

−650.00

{Hz}

650.00 Read only: Output frequency

without slip compensation

C0051
*

Output freq.
with slip
compensation
(MCTRL1−NOUT
+SLIP) or
Actual process
controller
value
(PCTRL1−ACT)

−650.00

{0.02

Hz}

650.00 The set value will be lost during

mains switching!
During operation without process
controller (C0238 = 2):

l

Read only: output frequency
with slip compensation
(MCTRL1−NOUT+SLIP)

During operation with process
controller (C0238 = 0, 1):

l

Selection if C0412/5 =
FIXED−FREE (not assigned)

l

Display if C0412/5 is linked to
a signal source

^ 324

C0052
*

Motor voltage
(MCTRL1−VOLT)

0

{V}

1000 Read only

C0053
*

DC−bus voltage
(MCTRL1−
DCVOLT)

0

{V}

1000 Read only

C0054
*

Apparent
motor current
(MCTRL1−
IMOT)

0.0

{A}

2000.0 Read only

C0056
*

Device
utilisation
(MCTRL1−
MOUT)

−255

{%}

255 Read only

The display value for the "Vector
control" or "Sensorless torque
control" operating mode can be
changed in C0311.