Transferring parameters to other standard devices, Parameter setting – Lenze E82xVxxxKxxxxx User Manual
Page 240
Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Transferring parameters to other standard devices
l
240
EDS82EV903 EN 3.0
9.3.5
Transferring parameters to other standard devices
Parameter settings can be easily copied from one standard device to another using the
keypad.
For this purpose, use "Param managm" in menu 7:
Copying parameter sets from the standard device into the keypad
Step
Key seq.
Action
1.
Connect the keypad to standard
device 1
2.
Inhibit controller
S
The drive coasts
3.
Select submenu 7.1, "Load/Store",
from "Param managm" in menu 7
z y Z Y
Use the arrow keys to change to the "Load/Store"
submenu
4.
Change to the code level
Z
Display C0002 "Param managm"
5.
Change to the parameter level
V
Display "0" and "READY"
6.
Select the correct copy function
The settings stored in the keypad are overwritten.
l
Copy all available parameter sets (PAR1 ... PAR4, if required FPAR1) into the keypad:
– Standard device with function
module application I/O,
INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen
z
Copy PAR1 ... PAR4 and FPAR1:
ð Set "80" "F1&PAR1−4−>Key"
– Standard device with all other
function modules
Copy PAR1 ... PAR4:
ð Set "20" "PAR1−4−>Keypad"
l
Only copy the module−specific parameter set FPAR1 into the keypad:
– Only possible with standard
devices including function
module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen:
z
Copy FPAR1:
ð Set "50" "FPAR1−>Keypad"
7.
Start copying
T V
The selected parameter sets are copied to the keypad.
"SAVING..." is displayed.
When "SAVING..." goes off, the copy process is
complete.
8.
Change to the code level
A
V
Display of the operating level
B
V
Display C0002 "Param managm"
9.
Enable controller
U
The drive operates again
10. Remove keypad from standard device
1