6 standard devices with a power of 55 kw, 1 mounting with fixing brackets (standard), Standard devices with a power of 55 kw – Lenze E82xVxxxKxxxxx User Manual

Page 89: Mounting with fixing brackets (standard), Mechanical installation

Advertising
background image

Mechanical installation

Standard devices with a power of 55 kW

Mounting with fixing brackets (standard)

5

l

89

EDS82EV903−3.0

5.6

Standard devices with a power of 55 kW

5.6.1

Mounting with fixing brackets (standard)

Mounting material required from the scope of supply:

Description

Use

Quantity

Fixing bracket

Drive controller fixing

4

Hexagon head cap screw M8 × 16 mm
(DIN 933)

Mounting of fixing bracket to the drive controller

4

Washer

Æ 8.4 mm (DIN 125)

For hexagon head cap screw

4

Spring washer

Æ 8 mm (DIN 127)

For hexagon head cap screw

4

Controller variant "2xx" (without fully assembled footprint filter)

For this mounting variant you require controller type E82EVxxxK4B2xx.

)

Note!

Before assembling the controller, please read the documentation for the
components connected on the supply side (mains choke, filter).

a

c1

e

b1

d

d1

b

l

c

³ 50 mm

³ 50 mm

g

m

k

0

³ 100 mm

³ 100mm

9300vec175

Fig. 5−23

Standard mounting with fixing brackets 55 kW



Loosen both screws to be able to remove the housing cover. The assembly kit is located under
the housing cover.

‚

Installation of mounting angles

ƒ

Dimensions

0

Arrange the controllers side by side with spacing to be able to disassemble the eyebolts.

Dimensions [mm]

8200 vector

a

b

b1

c

c1

d

d1

e

1)

g

k

m

E82EV553K4B2xx

340

672

591

28.5

283

615

38

285

11

28

18

1)

If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 8 mm.

Advertising