Technical data
Operation with increased rated power
Rated data for a mains voltage of 230 V
l
53
EDS82EV903 EN 3.0
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
1.1
2.2
P
rated
[hp]
1.5
3.0
8200 vector type
EMC filter integrated
E82xV751K2C0xx
2)
E82xV152K2C0xx
2)
Without EMC filter
E82xV751K2C2xx
2)
E82xV152K2C2xx
2)
Mains
1/N/PE
3/PE
1/N/PE
3/PE
Rated mains current
without mains choke
I
mains
[A]
−
−
−
−
with mains choke
I
mains
[A]
9.0
4.4
15.0
7.6
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
0
0.4
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
4.8
8.4
4 kHz sin
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
6.0
10.5
4 kHz sin
Power loss (operation with
I
N24
)
E82EV...
P
loss
[W]
60
100
E82DV... inside/outside
P
loss
[W]
20/40
33/67
E82CV... inside/cooler
P
loss
[W]
20/40
Dimensions
Dependent on the mounting variant (
^ 61)
Mass
E82EV...
m [kg]
1.2
1.6
E82DV...
m [kg]
1.2
1.6
E82CV...
m [kg]
0.9
1.1
1)