Parameter setting

Parameter setting with the XT EMZ9371BC keypad
Menu structure

9

l

252

EDS82EV903 EN 3.0

Description

Submenus

Main menu

Description

Display

No.

Display

No.

12

FIF system
bus

Configuration for the operation with the system bus (CAN)
function module and display of the contents of the CAN objects
Only active with the system bus (CAN) function module

12.1

CAN managem CAN communication parameters

12.2

Cfg CAN−IN1

CAN object 1

12.3

Cfg CAN−OUT1

12.4

Cfg CAN−IN2

CAN object 2

12.5

Cfg CAN−OUT2

12.6

Status words

Display of status words

12.7

CAN diagn

CAN diagnostics

Only active with standard devices from software version 2.2:
Change to the code level to display the contents of the data words. The contents of the data
words are displayed as hexadecimal values.

12.8

Mon IN1 W1−2 Contents of the 4 input words or 4 output words of CAN object

1
Analog words: 5DC0h

º 480 Hz

Digital words: Hexadecimal representation of the bits

12.9

Mon IN1 W3−4

12.10

Mon OUT1
W1−2

12.11

Mon OUT1
W3−4

12.12

Mon IN2 W1−2 Contents of the 4 input words or 4 output words of CAN object

2
Analog words: 5DC0h

º 480 Hz

Digital words: Hexadecimal representation of the bits

12.13

Mon IN2 W3−4

12.14

Mon OUT2
W1−2

12.15

Mon OUT2
W3−4

13

FIF−field bus

Configuration of the operation with fieldbus function modules
and display of the contents of the process data words
Only active with fieldbus function module

13.1

Identify

Display of the software version and the type of the fieldbus
function module

13.2

FIF managem

FIF communication parameters

13.3

POW setup

Process data from the master to the fieldbus function module

13.4

PIW setup

Process data from the fieldbus function module to the master

13.5

Com.err setup

Monitoring of the communication

ББББББББББББББББББББББББ

ББББББББББББББББББББББББ

ББББББББББББББББББББББББ

Change to the code level to display the contents of the data words. The contents of the data
words are displayed as decimal values.

13.6

Monit PIW

Display of the process data from the fieldbus function module
to the master

13.7

Monit POW

Display of the process data from the master to the fieldbus
function module

13.8

Monit FIF−IN

Display of the process data from the fieldbus function module
to the controller

13.9

Monit FIF−OUT

Display of the process data from the controller to the fieldbus
function module