Function library

Free interconnection of analog signals

Free configuration of analog outputs

10

l

335

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0419

v
(Cont.)

Possible analog signals for C0419

^ 332

26

Output frequency normalised without
slip (MCTRL1−NOUT−NORM)

27

Output frequency without slip
(MCTRL1−NOUT)

6 V/12 mA/5.85 kHz

º C0011

28

Actual process controller value
(PCTRL1−ACT)

29

Process controller setpoint
(PCTRL1−SET1)

6 V/12 mA/5.85 kHz

º C0011

30

Process controller output without
feedforward control (PCTRL1−OUT)

31

Ramp function generator input
(NSET1−RFG1−IN)

32

Ramp function generator output
(NSET1−NOUT)

33 (A)

PID controller output
(PCTRL1−PID−OUT)

34 (A)

Process controller output
(PCTRL1−NOUT)

35

Input signal at X3/8 (standard I/O) or
X3/1U or X3/1I (application I/O),
assessed with gain (C0414/1 or C0027)
and offset (C0413/1 or C0026)
(AIN1−OUT)

6 V/12 mA/5.85 kHz

º maximum

value of analog input signal (5 V,
10 V, 20 mA, 10 kHz)
Condition: The gain of the analog
input or frequency input is set to:
C0414/x, C0426 = 100 %

36

Input signal at frequency input X3/E1
and X3/E2, assessed with gain (C0426)
and offset (C0427) (DFIN1−OUT)

37

Motor potentiometer
output

×(MPOT1−OUT)

38 (A)

Input signal at X3/2U or X3/2I,
assessed with gain (C0414/2) and
offset (C0413/2) (AIN2−OUT)

40

AIF input word 1 (AIF−IN.W1)

Setpoints to the controller from
communication module on AIF
10 V/20 mA/10 kHz

º 1000

41

AIF input word 2 (AIF−IN.W2)

50

CAN−IN1.W1 or FIF−IN.W1

Setpoints to controller from
function module on FIF
10 V/20 mA/10 kHz

º 1000

51

CAN−IN1.W2 or FIF−IN.W2

52

CAN−IN1.W3 or FIF−IN.W3

53

CAN−IN1.W4 or FIF−IN.W4

60

CAN−IN2.W1

61

CAN−IN2.W2

62

CAN−IN2.W3

63

CAN−IN2.W4

255

Not assigned (FIXED−FREE)

C0108
*

Gain for analog
output X3/62
(AOUT1−GAIN)

128

0

{1}

255 Standard I/O: C0108 and C0420

are equal
Application I/O: C0108 and
C0420/1 are equal

^ 332

C0109
*

Offset for
analog output
X3/62 (AOUT1−
OFFSET)

0.00

−10.00

{0.01 V}

10.00 Standard I/O: C0109 and C0422

are equal
Application I/O: C0109 and
C0422/1 are equal

^ 332

C0420
*

Gain − analog
output X3/62
(AOUT1−GAIN)
Standard I/O

128

0

{1}

255 128

º Gain 1

C0420 and C0108 are equal

^ 332