Technical data – Lenze E82xVxxxKxxxxx User Manual

Page 54

Advertising
background image

Technical data

Operation with increased rated power
Rated data for a mains voltage of 230 V

4

l

54

EDS82EV903 EN 3.0

Typical motor power
Three−phase asynchronous
motor (4−pole)

P

rated

[kW]

4.0

7.5

P

rated

[hp]

5.0

10.0

8200 vector type

EMC filter integrated

E82xV302K2C0xx

E82xV552K2C0xx

2)

Without EMC filter

E82xV302K2C2xx

E82xV552K2C2xx

2)

Mains

3/PE

3/PE

Rated mains current

without mains choke

I

mains

[A]

18.7

with mains choke

I

mains

[A]

14.4

25.2

Output power +U

DC

, −U

DC

1)

P

DCres

[kW]

0

0

Rated output
current at
switching
frequency

2 kHz sin

I

r

[A]

14.4

27.0

4 kHz sin

Max. permissible
output current for
60 s at switching
frequency

2 kHz sin

I

max

[A]

18.0

33.8

4 kHz sin

Power loss (operation with
I

N24

)

E82EV...

P

loss

[W]

150

250

E82DV... inside/outside

P

loss

[W]

50/100

83/167

E82CV... inside/cooler

P

loss

[W]

50/100

83/167

Dimensions

Dependent on the mounting variant (

^ 61)

Mass

E82EV...

m [kg]

2.9

E82DV...

m [kg]

2.9

E82CV...

m [kg]

2.4

1)

Power supplied by the DC bus when operating with power−adapted motor

2)

Operation only permitted with mains choke (

^ 106)