Mechanical installation – Lenze E82xVxxxKxxxxx User Manual
Page 82
![background image](/manuals/566070/82/background.png)
Mechanical installation
Standard devices in the power range 15 ... 30 kW
Thermally separated mounting (push−through technique)
l
82
EDS82EV903−3.0
5.4.2
Thermally separated mounting (push−through technique)
For this mounting variant you require the controller type E82DV...
)
Note!
Before assembling the controller, please read the documentation for the
components connected on the supply side (mains choke, filter).
h
c1
c2
c3
h
d1
d2
d3
d2
d
b
a1
a
g
b1
e1
e
8200vec304
Fig. 5−18
Dimensions for thermally separated mounting 15 ... 30 kW
Dimensions [mm]
8200 vector
a
a1
b
b1
c1
c2
c3
d
d1
d2
d3
e
1)
e1
1)
g
h
E82DV153K4B
279.5 250 379.5 350
19
131
243
361.5
32
100
97
250 159.5
6
9
E82DV223K4B
E82DV303K4B
1)
If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 8 mm.
Cutout in the control cabinet
Dimensions [mm]
8200 vector
Width
Height
E82DV153K4B
236
336
E82DV223K4B
E82DV303K4B