2 rated data for 400 v mains voltage, Rated data for 400 v mains voltage, Technical data – Lenze E82xVxxxKxxxxx User Manual

Page 37

Advertising
background image

Technical data

Operation with rated power (normal operation)

Rated data for 400 V mains voltage

4

l

37

EDS82EV903 EN 3.0

4.4.2

Rated data for 400 V mains voltage

Basis of the data

AC mains connection

U

r

3/PE AC 320 V − 0 % ... 440 V + 0 %; 45 Hz − 0 % ... 65 Hz + 0 %

DC−mains connection
(alternatively)

U

DC

DC 450 V − 0 % ... 620 V + 0 %

Output voltage

With mains choke

V

M

3 ~ 0 ... approx. 94 % U

mains;

0 ... 650 Hz

without mains choke

V

M

3 ~ 0 ... U

mains;

0 ... 650 Hz

Periodic load change

60 s overcurrent with I

max

and 120 s base load with 75 % I

rated

Typical motor power
Three−phase asynchronous
motor (4−pole)

P

rated

[kW]

0.55

0.75

P

rated

[hp]

0.75

1.0

8200 vector type

EMC filter integrated

E82xV551K4C0xx

E82xV751K4C0xx

Without EMC filter

E82xV551K4C4xx

E82xV751K4C2xx

Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)

without mains choke

I

mains

[A]

2.5

3.3

with mains choke

I

mains

[A]

2.0

2.3

Output power +U

DC

, −U

DC

1)

P

DCres

[kW]

0.3

0.1

Rated output
current at
switching
frequency

2 kHz sin

I

r

[A]

1.8

2.4

4 kHz sin

8 kHz sin

I

r

[A]

1.8

2.4

16 kHz sin

2)

I

r

[A]

1.2

1.6

Max. permissible
output current for
60 s at switching
frequency

2 kHz sin

I

max

[A]

2.7

3.6

4 kHz sin

8 kHz sin

I

max

[A]

2.7

3.6

16 kHz sin

2)

I

max

[A]

1.8

2.4

Power loss (operation with I

N8

)

E82EV...

P

loss

[W]

50

60

E82DV... inside/outside

P

loss

[W]

17/33

20/40

E82CV... inside/cooler

P

loss

[W]

17/33

20/40

Dimensions

Dependent on the mounting variant (

^ 61)

Mass

E82EV...

m [kg]

1.2

E82DV...

m [kg]

1.2

E82CV...

m [kg]

0.9

1)

Power supplied by the DC bus when operating with power−adapted motor

2)

Switching frequency is reduced to 4 kHz if

J reaches max. − 5 °C

Advertising