Function library – Lenze E82xVxxxKxxxxx User Manual
Page 379
![background image](/manuals/566070/379/background.png)
Function library
Code table
l
379
EDS82EV903 EN 3.0
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0001
v
Setpoint
selection
(operating
mode)
0
l
A change in C0001 triggers the
below−mentioned changes in
C0412 and C0410 if C0412 has
not been configured freely
before.
l
If C0412 has been configured
freely before (check: C0005 =
255), C0001 does not affect
C0412 and C0410. You must
link the signals manually.
l
Free configuration in C0412 or
C0410 does not affect C0001!
l
Control can be carried out via
terminals as well as via
PC/keypad.
^ 296
0
Setpoint selection via AIN1 (X3/8 or
X3/1U, X3/1I)
l
C0412/1 and C0412/2 are
linked to analog input 1
(C0412/1 = 1, C0412/2 = 1).
l
C0410 remains unchanged.
1
Setpoint selection via keypad or
parameter channel of an AIF bus
module
l
In C0412, the link to the analog
input is disconnected
(C0412/1 = 255,
C0412/2 = 255).
l
Setpoint selection via C0044 or
C0046.
l
C0410 remains unchanged.
2
Setpoint selection via AIN1 (X3/8 or
X3/1U, X3/1I)
l
C0412/1 and C0412/2 are
linked to analog input 1
(C0412/1 = 1, C0412/2 = 1).
l
C0410 remains unchanged.
3
Setpoint selection via process data
channel of an AIF bus module
l
C0001 = 3 must be set for the
setpoint selection via process
data channel of an AIF bus
module (types 210x, 211x,
213x, 217x)! Otherwise the
process data will not be
evaluated.
l
C0412/1 and C0412/2 are
linked to analog input words
AIF−IN.W1 and AIF−IN.W2
(C0412/1 = 10, C0412/2 = 11).
l
C0410/1 ... C0410/16 are
linked to the individual bits of
the AIF control word (AIF−CTRL)
(C0410/1 = 10 ... C0410/16 = 2
5).