background image

Function library

Free interconnection of analog signals

Free configuration of analog input signals

10

l

329

EDS82EV903 EN 3.0

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0412

v

Free
configuration
of analog input
signals

Linking analog signal sources to internal analog
signals

A selection in C0005 or C0007 is
copied to the corresponding
subcode of C0412. A change in
C0412 sets C0005 = 255 and
C0007 = 255!

^ 328

1 Setpoint 1

(NSET1–N1)

1

Analog input 1 (AIN1−OUT):
X3/8 (standard I/O)
X3/1U or X3/1I (application I/O)

Either NSET1−N1 or
NSET1−N2 active
Changeover with
C0410/17

Parameter
channel:
C0046

2 Setpoint 2

(NSET1−N2)

1

Parameter
channel:
C0044

3 Additional

setpoint
(PCTRL1−NADD)

255

Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module

Acts additively on
NSET1−N1,
NSET1−N2, JOG
values and the

j

functionof the
keypad

Parameter
channel:
C0049

4 Process

controller
setpoint 1
(PCTRL1−SET1)

255

Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module

Application of the motor
potentiometer for the selection of
the process controller setpoint
(C0142/4 = 3) is only permissible
in conjunction with the
application I/O!

5 Actual process

controller
value
(PCTRL1−ACT)

255

Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module

Parameter
channel:
C0051 if
C0238 = 1,
2

6 Torque

setpoint or
torque limit
(MCTRL1−
MSET)

255

Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module

l

Observe C0014!

l

An actual torque
value is not
required.

l

16384

º 100 %

torque setpoint

l

Condition if
selection via
terminal
(C0412/6 = 1, 2 or
4):
– The gain of the

analog input is
set to: C0414/x,
C0426 =
32768/C0011
[%]

Parameter
channel:
C0047

7 Reserved

255

Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module

8 MCTRL1−VOLT−

ADD

255

Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module

For special applications only.
Alterations only after consultation
with Lenze!

9 MCTRL1−PHI−

ADD

255

Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module