2 quick stop, Quick stop, Function library – Lenze E82xVxxxKxxxxx User Manual

Page 289

Advertising
background image

Function library

Acceleration, deceleration, braking, stopping

Quick stop

10

l

289

EDS82EV903 EN 3.0

10.6.2

Quick stop

Description

Quick stop decelerates the drive to standstill according to the deceleration time set under
C0105, as soon as the signal DCTRL1−QSP is activated.

If the output frequency falls below the threshold C0019, the automatic DC injection brake
(DCB) is activated. After the holding time (C0106) the controller sets pulse inhibit (display:

c).
Quick stop acts on

ƒ

the main setpoint (NSET1−N1, NSET1−N2).

ƒ

the additional setpoint (PCTRL1−NADD).

ƒ

the process controller setpoint 1 (PCTRL1−SET1) (only application I/O).

)

Note!

The S−shaped ramp (C0182) has also an effect on quick stop! Therefore the real
deceleration time is longer than set under C0105.
Reduce the time setting under C0105 to reach the desired deceleration time
for quick stop.

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0105 Deceleration

time − quick
stop (QSP)

5.00

0.00

{0.02 s}

1300.00

l

Quick stop (QSP) brakes the
drive to standstill with the
ramp set in C0105.

l

If the output frequency falls
below the theshold set in
C0019, the DC injection brake
(DCB) will be activated.

l

The S−ramp (C0182) also
affects quick stop!
– Select shorter times in C0105

accordingly to achieve the
desired deceleration times
for quick stop.

– In C0311 the S−ramp for

quick stop can be
deactivated (from software
version 3.1).

^ 289

C0019 Operating

threshold −
automatic DC
injection brake
(auto DCB)

0.10

0.00
= inactive

{0.02

Hz}

650.00 Hold time

ð C0106

Deactivate automatic DC injection
brake (auto DBC):

l

at active lower frequency
limitation (C0239)

l

at operating mode C0014 = 5

In the case of a max. output
frequency > 50 Hz (C0011), the
switching threshold of the auto
DCB in C0019 must be increased.

^ 292

C0106 Hold time −

automatic DC
injection brake
(auto DCB)

0.50

0.00
= auto DCB
inactive

{0.01 s}

999.00

=

¥

Hold time if DC injection braking
is triggered because the value falls
below C0019

^ 292