Technical data – Lenze E82xVxxxKxxxxx User Manual
Page 42
![background image](/manuals/566070/42/background.png)
Technical data
Operation with rated power (normal operation)
Rated data for 400 V mains voltage
l
42
EDS82EV903 EN 3.0
Typical motor power −
three−phase asynchronous
motor (4−pole)
P
rated
[kW]
45
55
P
rated
[hp]
60
75
8200 vector type
With mains filter
E82xV453K4B3xx
E82xV553K4B3xx
Without mains filter
E82xV453K4B2xx
3)
E82xV553K4B2xx
3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke/mains
filter
I
mains
[A]
−
−
With mains choke/mains filter
I
mains
[A]
80
100
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
5.1
0
Rated output
current at
switching
frequency
1 kHz sin
I
r
[A]
89
110
2 kHz sin
4 kHz sin
8 kHz sin
I
r
[A]
59
4)
76
4)
16 kHz sin
2)
I
r
[A]
46
60
1 kHz
I
r
[A]
89
110
2 kHz
4 kHz
8 kHz
I
r
[A]
89
110
16 kHz
2)
I
r
[A]
54
77
Max. permissible
output current for
60 s at switching
frequency
1 kHz sin
I
max
[A]
134
165
2 kHz sin
4 kHz sin
8 kHz sin
I
max
[A]
88
4)
114
4)
16 kHz sin
2)
I
max
[A]
69
78
1 kHz
I
max
[A]
134
165
2 kHz
4 kHz
8 kHz
I
max
[A]
134
165
16 kHz
2)
I
max
[A]
81
100
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
1100
1470
E82DV... inside/outside
P
loss
[W]
367/733
490/980
E82CV... inside/cooler
P
loss
[W]
−
−
Dimensions
Dependent on the mounting variant (
^ 61)
Mass with mains
filter
E82EV...
m [kg]
60
66
E82DV...
m [kg]
60
66
E82CV...
m [kg]
−
−
Mass without
mains filter
E82EV...
m [kg]
36
38
E82DV...
m [kg]
36
38
E82CV...
m [kg]
−
−
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if
J reaches max. − 5 °C
3)
Operation only permitted with mains choke (
^ 106)
4)
Only operate with automatic switching frequency reduction (C144 = 1). Ensure that the specified current values are
not exceeded.