12 free interconnection of digital signals, 1 free configuration of digital input signals, Function library – Lenze E82xVxxxKxxxxx User Manual

Page 343

Advertising
background image

Function library

Free interconnection of digital signals

Free configuration of digital input signals

10

l

343

EDS82EV903 EN 3.0

10.12

Free interconnection of digital signals

10.12.1

Free configuration of digital input signals

Description

ƒ

Internal digital signals can be freely assigned to external digital signal sources. It is
thus possible to achieve a freely configured control of the controller
– Digital inputs X3/E1 ... X3/E6
– Digital process data input words

ƒ

A signal source can be assigned to several targets. Please ensure reasonable
assignments. Otherwise it is possible to activate functions which cannot be
operated together (e.g. a digital signal linked with quick stop and DC braking at the
same time).

)

Note!

Use C0007 to configure some internal digital signals with the digital inputs
X3/E1 ... X3/E4 block by block. The corresponding subcodes of C0410 will be
adapted automatically.

)

Note!

The default setting defines the signals for the most frequently used function
modules of the standard I/O and application I/O. If the default setting is
changed, all unused signals must be set to FIXED−FREE in order to ensure
trouble−free operation.

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0410

v

Free
configuration
of digital input
signals

Linking of digital signal sources to internal
digital signals

A selection in C0007 is copied to
the corresponding subcode of
C0410. A change in C0410 sets
C0007 = 255!

^ 343

1 NSET1−JOG1/3

NSET1−JOG1/3
/5/7 (A)

1

Digital input X3/E1

Selection of fixed
setpoints
C0410/1

C0410/

2

C0410/33

LOW LOW LOW
HIGH LOW LOW
LOW HIGH LOW
...

...

...

HIGH HIGH HIGH

Active
C0046
JOG1
JOG2
...
JOG7

2 NSET1−JOG2/3

NSET1−JOG2/3
/6/7 (A)

2

Digital input X3/E2

3 DCTRL1−CW/

CCW

4

Digital input X3/E4

CW = clockwise
rotation
CCW =
counter−clockwise
rotation

LOW
HIGH

4 DCTRL1−QSP

255

Not assigned (FIXED−FREE)

Quick stop (via terminal
LOW−active)

5 NSET1−RFG1−

STOP

255

Not assigned (FIXED−FREE)

Stop main setpoint of ramp
function generator

Advertising