Function library – Lenze E82xVxxxKxxxxx User Manual
Page 337
![background image](/manuals/566070/337/background.png)
Function library
Free interconnection of analog signals
Free configuration of analog outputs
l
337
EDS82EV903 EN 3.0
Output signal for selection 7
The output signal for selection 7 is proportional to the output frequency with slip
compensation.
U
out
[V] + 6, 00 V @
f * C0011
C0011 * C0010
U
out
Output signal
f
Output frequency
C0010
Minimum output frequency
C0011
Maximum output frequency
Output signal for selection 8
During operation without process controller, the output signal for selection 8 is
proportional to the output frequency without slip compensation.
Application example for selection 6
The output signal acts reciprocally with the output frequency. This signal can be used for
the display of processing times (e.g. for continuous furnace products).
Example: output signal = 0 ... 10 V
U
out
[V] + 1.00 V @ C0011
f
@ C0420
128
U
out
Output signal
f
Output frequency
C0011
Maximum output frequency
C0420
Analog output gain
6.00
5.00
4.00
3.00
2.00
1.00
0.00
0
10
20
30
40
50
60
Uout
[V]
f [Hz]
C0420 = 128
8200vec536
Fig. 10−15
Output signal of the function "1/output frequency"