Function library

Individual summary of drive parameters in the user menu

10

l

373

EDS82EV903 EN 3.0

10.17

Individual summary of drive parameters in the user menu

Description

ƒ

Quick access to ten selected codes via the user menu of the keypad

ƒ

With password protection, an individual code selection can be prepared which can
only be changed by e.g. your operating personnel.

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0517
*

v

User menu

l

After mains switching or in the

g function the code from
C0517/1 is displayed.

l

In the Lenze setting the user
menu contains the most
important codes for
commissioning the operating
mode "V/f characteristic control
with a linear characteristic"

l

If the password protection is
active, only the codes entered
in C0517 can be freely accessed

l

If less than 10 codes are
required, assign the value "0"
(zero) to the memory locations
not used. Please observe that
the software automatically
assigns code C0050 to a
memory location that is not
used, if it has not been
explicitly assigned to another
memory location.

^ 373

1 Memory 1

50

C0050

Output frequency (MCTRL1−NOUT)

2 Memory 2

34

C0034

Range of analog setpoint selection

3 Memory 3

7

C0007

Fixed configuration of digital input
signals

4 Memory 4

10

C0010

Minimum output frequency

5 Memory 5

11

C0011

Maximum output frequency

6 Memory 6

12

C0012

Acceleration time main setpoint

7 Memory 7

13

C0013

Deceleration time main setpoint

8 Memory 8

15

C0015

V/f rated frequency

9 Memory 9

16

C0016

V

min

boost

10 Memory 10

2

C0002

Parameter set transfer

Possible entries for C0517

xxxx

All codes apart from the codes labelled
with "(A)".

Syntax:
Codes: C0517/x = cccc
Subcodes: C0517/x = cccc.ss

Adapt the user menu

Enter the desired code numbers or subcode numbers into the subcodes of C0517.