Braking operation, General electrical data, Rated data – Lenze E82xVxxxKxxxxx User Manual

Page 488

Advertising
background image

Braking operation

Braking operation with external brake resistor
8200 vector 15 ... 90 kW

13

l

488

EDS82EV903 EN 3.0

General electrical data

Protection EMB9351/EMB9352

Type of protection

EN 60529

IP 10
IP 20 with installed terminal cover
IP 41 on the side of the heatsink in push−through design

NEMA 250

Protection against accidental contact in accordance with type 1

Insulation resistance

EN 61800−5−1

Overvoltage category III
Reduction from 2000 m: overvoltage category II

Discharge current

EN 61800−5−1

< 3.5 mA

Observe regulations and safety
instructions!

Protective insulation
of control circuits

EN 61800−5−1

Safe mains isolation: Double/reinforced insulation

Rated data

Brake chopper EMB9352

Supply voltage V

rated

[V DC]

270 ... 775

Switching threshold V

DC

[V DC]

375/725/765

Adjustable

Peak braking current Î

[A DC]

42

for 60 s

Max. continuous current
I

rated

[V DC]

25

Peak braking power P

Bmaxv (

V

DC

)

375 V DC

[kW]

15

725 V DC

[kW]

30

765 V DC

[kW]

32

Continuous braking power P

Bd

(V

DC

)

375 V DC

[kW]

9

725 V DC

[kW]

18

765 V DC

[kW]

19

Minimum permissible resistance
value

(

V

DC

)

375 V DC

[

W]

9

±10%

725 V DC

[

W]

18

±10%

765 V DC

[

W]

18

±10%

Switch−on cycle

Max. 60 s of braking at peak braking current, followed by min. 60 s

recovery time

Heat

[kWs]

See technical data for the external resistor

Dimensions

Dependent on the mounting variant,

^ documentation for the brake

chopper

Mass

EMB9352−E

[kg]

2.6

Standard mounting

EMB9352−C

[kg]

1.5

Cold plate technique