Technical data – Lenze E82xVxxxKxxxxx User Manual
Page 36
![background image](/manuals/566070/36/background.png)
Technical data
Operation with rated power (normal operation)
Rated data for a mains voltage of 230 V
l
36
EDS82EV903 EN 3.0
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
5.5
7.5
P
rated
[hp]
7.5
10.0
8200 vector type
EMC filter integrated
E82xV552K2C0xx
E82xV752K2C0xx
3)
Without EMC filter
E82xV552K2C2xx
E82xV752K2C2xx
3)
Mains
3/PE
3/PE
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke
I
mains
[A]
29.3
−
with mains choke
I
mains
[A]
21.0
28.0
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
1.1
0
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
22.5
28.6
4 kHz sin
8 kHz sin
I
r
[A]
22.5
28.6
16 kHz sin
2)
I
r
[A]
14.6
18.6
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
33.8
42.9
4 kHz sin
8 kHz sin
I
max
[A]
33.8
42.9
16 kHz sin
2)
I
max
[A]
21.9
27.9
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
250
320
E82DV... inside/outside
P
loss
[W]
83/167
107/213
E82CV... inside/cooler
P
loss
[W]
83/167
107/213
Dimensions
Dependent on the mounting variant
(
^ 61
)
Mass
E82EV...
m [kg]
3.6
E82DV...
m [kg]
3.6
E82CV...
m [kg]
3.0
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if
J reaches max. − 5 °C
3)
Operation only permitted with mains choke (