Table of attributes

The data given in the table of attributes is required to write your own programs. It contains
all information for parameter communication with the controller.

How to read the table of attributes:

Column

Meaning

Entry

Code

Name of the Lenze code

Cxxxx

Index

dec

Index under which the parameter is
addressed. The subindex of array
variables corresponds to the Lenze
subcode number.

Is only required for control via
INTERBUS, PROFIBUS−DP or system
bus (CAN).

hex

Data

DS

Data structure

E

Single variable (only one parameter
element)

A

Array variable (several parameter
elements)

DT

Data type

B8

1 byte bit−coded

B16

2 bytes bit−coded

B32

4 bytes bit−coded

FIX32

32 bit value with sign;
decimal with four decimal positions

I32

4 bytes with sign

U32

4 bytes without sign

VS

ASCII string

Format

LECOM format

VD

ASCII decimal format

VH

ASCII hexadecimal format

VS

String format

VO

Octet string format for data blocks

DA

Number of array elements
(subcodes)

xx

DL

Data length in bytes

Access

R/W
Remote

Access authorisation for LECOM

Ra

Reading is always permitted

Wa

Writing is always permitted

W

Writing is restricted

R/W CAN

Access authorisation for system bus
(CAN)

Ra

Reading is always permitted

Wa

Writing is always permitted

W

Writing is restricted

Condition

Condition for writing

CINH

Writing only permitted when
controller is inhibited