Function library

Code table

10

l

405

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0265

v

Motor
potentiometer
configuration

3

0

Starting value = power off

l

Starting value: output
frequency which is approached
with Tir (C0012) after mains
connection when the motor
potentiometer is activated:
– "Power off" = actual value

when the power is switched
off

– "C0010": minimum output

frequency from C0010. The
setpoint must have
exceeded C0010 previously.

– "0" = output frequency of 0

Hz

l

C0265 = 3, 4, 5:
– QSP also decelerates the

motor potentiometer along
the QSP ramp (C0105)

^ 307

1

Starting value = C0010

2

Starting value = 0

3

Staring value = power off
QSP if UP/DOWN = LOW

4

Starting value = C0010
QSP if UP/DOWN = LOW

5

Starting value = 0
QSP if UP/DOWN = LOW

C0304 Service codes

Alterations by Lenze service only!

...
C0309