Function library
Configuration of analog and digital setpoints and actual values
Setpoint changeover (hand/remote changeover)
l
314
EDS82EV903 EN 3.0
Example
ƒ
Invert X3/E6 with C0411 = 32.
ƒ
Assign X3/E6 to the subcode C0410/17 with C0410/17 = 6.
ƒ
The setpoint can be selected under C0044 using the keypad or PC.
ƒ
If C0411 = 0 is set, the remote operation is active again.
Influence on other setpoints
ƒ
JOG frequency are not effected by a manual/remote changeover.
ƒ
Function
j of the keypad E82ZBC simultaneously acts on NSET1−N1 and NSET−N2.
– Use C0046 (NSET1−N1) and C0044 (NSET1−N2) for separated setpoint selection.
)
Note!
The keypad key
s is not active in manual operation!