Function library

Free interconnection of analog signals
Free configuration of analog input signals

10

l

328

EDS82EV903 EN 3.0

10.11

Free interconnection of analog signals

10.11.1

Free configuration of analog input signals

Description

ƒ

Internal analog signals can be freely assigned to external analog signal sources:
– Analog inputs (X3/8, X3/1U, X3/2U, X3/1I, X3/2I)
– Frequency input
– Function Motor potentiometer"
– Analog process data input words

ƒ

A signal source can be assigned to several targets.

)

Note!

Use C0005 to configure some of the signal sources for analog inputs. The
corresponding subcodes of C0412 will be adapted automatically.

)

Note!

The default setting defines the signals for the most frequently used function
modules of the standard I/O and application I/O. If the default setting is
changed, all unused signals must be set to FIXED−FREE in order to ensure
trouble−free operation.