Function library – Lenze E82xVxxxKxxxxx User Manual

Page 338

Advertising
background image

Function library

Free interconnection of analog signals
Free configuration of analog process data output words

10

l

338

EDS82EV903 EN 3.0

10.11.3

Free configuration of analog process data output words

Description

ƒ

The analog process data output words can be freely assigned to internal analog
process signals or monitoring signals. The controller outputs a value proportional to
the internal signal on the bus. The normalisation is indicated under C0421.

ƒ

A signal source can be assigned to several targets.

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0421
*

v

Free
configuration
of analog
process data
output words

Output of analog signals to bus

^ 338

1 AIF−OUT.W1

8

Operation with process controller
(C0238 = 0, 1):
Actual process controller value
(PCTRL1−ACT)
Operation without process controller
(C0238 = 2):
Output frequency without slip
(MCTRL1−NOUT)

2 AIF−OUT.W2

0

Output frequency
(MCTRL1−NOUT+SLIP)

3 CAN−OUT1.W1

/ FIF−OUT.W1

255

Not assigned (FIXED−FREE)

l

CAN−OUT1.W1 and
FIF−OUT.W1 are digitally
defined in the Lenze setting
and assigned to the 16 bits of
the controller status word 1
(C0417)

l

Before assigning an analog
signal source (C0421/3

¹ 255),

first delete the digital
assignment (C0417/x = 255)!
Otherwise, the output signal
would be wrong

4 CAN−OUT1.W2

/ FIF−OUT.W2

255

Not assigned (FIXED−FREE)

5 CAN−OUT1.W3

/ FIF−OUT.W3

255

Not assigned (FIXED−FREE)

6 CAN−OUT1.W4

/ FIF−OUT.W4

255

Not assigned (FIXED−FREE)

7 CAN−OUT2.W1

255

Not assigned (FIXED−FREE)

8 CAN−OUT2.W2

255

Not assigned (FIXED−FREE)

9 CAN−OUT2.W3

255

Not assigned (FIXED−FREE)

10 CAN−OUT2.W4

255

Not assigned (FIXED−FREE)