Function library – Lenze E82xVxxxKxxxxx User Manual

Page 382

Advertising
background image

Function library

Code table

10

l

382

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0003
*

v

Saving
parameters
non−volatilely

1

0

Do not save parameters in the EEPROM Data loss after mains switch−off

1

Always save parameters in the
EEPROM

l

Active after every mains
connection

l

Cyclic alteration of parameters
via bus module is not
permissible

3

Save your own basic setting in the
EEPROM

Afterwards save parameter set 1
as own basic setting with
C0002 = 9

C0004
*

Bar graph
display

56

1

{Code

no.}

989

l

The bar graph display shows
the selected value in % after
mains connection

l

Range −180 % ... +180 %

56 = device utilisation (C0056)

C0005

v

Fixed
configuration
of analog input
signals

0

Change of C0005 is copied into
the corresponding subcode of
C0412. Free configuration in
C0412 sets C0005 = 255!
Observe the following in case of
configurations with frequency
input:

l

Activate the frequency input
X3/E1, X3/E2 with C0410/24 =
1.

l

Delete all existing signal
connections of the digital
inputs in C0410 used by the
frequency input.

l

Configure frequency input with
C0425 and C0426

^ 328

0

Setpoint for speed control via X3/8 or
X3/1U, X3/1I

1

Setpoint for speed control via X3/8
with setpoint summation via
frequency input

2

Setpoint for speed control via
frequency input with setpoint
summation via X3/8

3

Setpoint for speed control via
frequency input, torque limitation via
X3/8 (power control)

4

Setpoint for sensorless torque control
via X3/8, speed limitation via C0011

Only active if C0014 = −5− (torque
selection)

5

Setpoint for sensorless torque control
via X3/8, speed limitation via
frequency input

6

Controlled operation; setpoint via X3/8
with digital feedback via frequency
input

7

Controlled operation, setpoint via
frequency input X3/E1 with analog
feedback via X3/8

200

All digital and analog input signals are
from the fieldbus function module on
FIF (e.g. INTERBUS, PROFIBUS−DP,
CANopen or DeviceNet)

Sets C0410/x = 200 and C0412/x
= 200

255

Free configuration in C0412

Read only
Do not change C0005 since
settings in C0412 may get lost