Function library – Lenze E82xVxxxKxxxxx User Manual

Page 363

Advertising
background image

Function library

Display of operating data, diagnostics

Display of operating data

10

l

363

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0050
*

uSEr

Output freq.
(MCTRL1−
NOUT)

−650.00

{Hz}

650.00 Read only: Output frequency

without slip compensation

C0051
*

Output freq.
with slip
compensation
(MCTRL1−NOUT
+SLIP) or
Actual process
controller
value
(PCTRL1−ACT)

−650.00

{0.02

Hz}

650.00 The set value will be lost during

mains switching!
During operation without process
controller (C0238 = 2):

l

Read only: output frequency
with slip compensation
(MCTRL1−NOUT+SLIP)

During operation with process
controller (C0238 = 0, 1):

l

Selection if C0412/5 =
FIXED−FREE (not assigned)

l

Display if C0412/5 is linked to
a signal source

^ 324

C0052
*

Motor voltage
(MCTRL1−VOLT)

0

{V}

1000 Read only

C0053
*

DC−bus voltage
(MCTRL1−
DCVOLT)

0

{V}

1000 Read only

C0054
*

Apparent
motor current
(MCTRL1−
IMOT)

0.0

{A}

2000.0 Read only

C0056
*

Device
utilisation
(MCTRL1−
MOUT)

−255

{%}

255 Read only

The display value for the "Vector
control" or "Sensorless torque
control" operating mode can be
changed in C0311.

C0061
*

Heatsink
temperature

0

{

°C}

255 Read only

l

If the heatsink temperature
>

J

max

− 5 °C:

– Warning OH is provided
– Switching frequency is

reduced to 4 kHz if C0144 = 1

l

If the heatsink temperature
>

J

max

:

– Controller sets TRIP OH

C0138
*

Process
controller
setpoint 1
(PCTRL1−SET1)

0.00

−650.00

{0.02

Hz}

650.00 The set value will be lost during

mains switching!

l

Selection if C0412/4 =
FIXED−FREE

l

Display if C0412/4

¹

FIXED−FREE

^ 322

C0189
*
(A)

Output signal −
follow−up
controller
(PCTRL1−FOLL1−
OUT)

−650.00

{0.02

Hz}

650.00 Read only

Follow−up controller =
PCTRL1−FOLL1

C0320
(A)

Actual process
controller value
(PCTRL1−ACT)

−650.00

{0.02

Hz}

650.00 Read only

C0321
(A)

Process
controller
setpoint
(PCTRL1−SET)

−650.00

{0.02

Hz}

650.00 Read only