Function library – Lenze E82xVxxxKxxxxx User Manual
Page 398
![background image](/manuals/566070/398/background.png)
Function library
Code table
l
398
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0150
*
Drive controller
status word 1
(parameter
channel)
Bit
Assignment
l
Query of the drive controller
status via parameter channel.
The most status information is
summarised as bit pattern
l
Some bits can be freely linked
with internal digital signals
l
Configuration in C0417
l
In the keypad: Display only
(hexadecimal)
0
Mapping of C0417/1
1
0
1
Pulse inhibit (DCTRL1−IMP)
Power outputs enabled
Power outputs inhibited
2
Mapping of C0417/3
3
Mapping of C0417/4
4
Mapping of C0417/5
5
Mapping of C0417/6
6
0
1
Output frequency = 0
(DCTRL1−NOUT=0)
False
True
7
0
1
Controller inhibit (DCTRL1−CINH)
Controller released
Controller inhibited
11|10|9
|8
Device status
0000 Device initialisation
0001 Mains voltage off (with external supply
of the control section of the drive
controller)
0010 Switch−on inhibit
0011 Operation inhibited
0100 Flying restart circuit active
0101 DC injection brake active
0110 Operation enabled
0111 Message active
1000 Fault active
12
0
1
Overtemperature warning
(DCTRL1−OH−WARN)
No warning
J
max
− 5
°C reached
13
0
1
DC bus overvoltage (DCTRL1−OV)
No overvoltage
Overvoltage
14
Mapping of C0417/15
15
Mapping of C0417/16
C0151
*
Controller
status word 2
(parameter
channel)
Bit
Assignment
l
The bits can be freely linked to
internal digital signals
l
Configuration in C0418
l
Keypad: read only
(hexadecimal)
0 ... 15
Display of C0418/1 ... C0418/16
C0152
(A)
Service code
Alterations by Lenze service only!