Function library – Lenze E82xVxxxKxxxxx User Manual

Page 398

Advertising
background image

Function library

Code table

10

l

398

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0150

*

Drive controller
status word 1
(parameter
channel)

Bit

Assignment

l

Query of the drive controller
status via parameter channel.
The most status information is
summarised as bit pattern

l

Some bits can be freely linked
with internal digital signals

l

Configuration in C0417

l

In the keypad: Display only
(hexadecimal)

0

Mapping of C0417/1

1

0
1

Pulse inhibit (DCTRL1−IMP)
Power outputs enabled
Power outputs inhibited

2

Mapping of C0417/3

3

Mapping of C0417/4

4

Mapping of C0417/5

5

Mapping of C0417/6

6

0
1

Output frequency = 0
(DCTRL1−NOUT=0)
False
True

7

0
1

Controller inhibit (DCTRL1−CINH)
Controller released
Controller inhibited

11|10|9
|8

Device status

0000 Device initialisation
0001 Mains voltage off (with external supply

of the control section of the drive
controller)

0010 Switch−on inhibit
0011 Operation inhibited
0100 Flying restart circuit active
0101 DC injection brake active
0110 Operation enabled
0111 Message active
1000 Fault active

12

0
1

Overtemperature warning
(DCTRL1−OH−WARN)
No warning

J

max

− 5

°C reached

13

0
1

DC bus overvoltage (DCTRL1−OV)
No overvoltage
Overvoltage

14

Mapping of C0417/15

15

Mapping of C0417/16

C0151

*

Controller
status word 2
(parameter
channel)

Bit

Assignment

l

The bits can be freely linked to
internal digital signals

l

Configuration in C0418

l

Keypad: read only
(hexadecimal)

0 ... 15

Display of C0418/1 ... C0418/16

C0152
(A)

Service code

Alterations by Lenze service only!