Function library

Free interconnection of analog signals
Free configuration of analog input signals

10

l

330

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0412

v
(Cont.)

Possible analog signal sources for
C0412

^ 328

0

Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module

1

Analog input 1 (AIN1−OUT)
X3/8 (standard I/O)
X3/1U or X3/1I (application I/O)

2

Frequency input (DFIN1−OUT)

Observe C0410/24, C0425, C0426,
C0427

3

Motor potentiometer (MPOT1−OUT)

4 (A)

Analog input 2 (AIN2−OUT)
X3/2U or X3/2I

5 ... 9

Input signal is constant = 0 (FIXED0)

10

AIF input word 1 (AIF−IN.W1)

Only evaluated if C0001 = 3!

11

AIF input word 2 (AIF−IN.W2)

20

CAN−IN1.W1 or FIF−IN.W1

± 24000

º ± 480 Hz

2

14

º 100 % rated motor torque

21

CAN−IN1.W2 or FIF−IN.W2

22

CAN−IN1.W3 or FIF−IN.W3

23

CAN−IN1.W4 or FIF−IN.W4

30

CAN−IN2.W1

31

CAN−IN2.W2

32

CAN−IN2.W3

33

CAN−IN2.W4

200

Word−by−word signal assignment of
the fieldbus function module to FIF
(e.g. INTERBUS or PROFIBUS−DP)

Also see C0005

228 (A) PCTRL1−ACT
229 (A) PCTRL1−SET
230 (A) PCTRL1−OUT
231 (A) NSET1−RFG1−IN
232 (A) NSET1−NOUT
233 (A) PCTRL1−PID−OUT
234 (A) PCTRL1−NOUT
255

Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module

Either NSET1−N1 or NSET1−N2
active

Signal linkage

The internal analog signals are linked with an external signal source by entering the
selection figure of the external signal in the corresponding subcode of C0412. C0412 can
be different for the parameter sets.