Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Remote parameter setting for system bus participants
l
244
EDS82EV903 EN 3.0
9.3.7
Remote parameter setting for system bus participants
If controllers are linked via the system bus (CAN), remote parameterisation of all other
nodes of the system bus is possible from a central point in the network.
For this purpose, the "Remote para" menu can be used:
Step
Key seq.
Action
1.
Select menu 3, "Remote para"
z y Z Y
Change to the "Remote para" menu using the arrow
keys
2.
Change to the code level
Z
Display of code C0370 "CANremot para"
3.
Change to the parameter level
V
Display of the current parameter value:
"0" = OFF
4.
Set the node address of the system bus
node the remote parameterisation is
to be carried out for
A
z
Select node address
Display of "Nodexx"
B
T V
Confirm node address
5.
Change to the code level
A
V
Display of the operating level
B
V
Display of C0370 "CANremot para"
6.
Set parameters
All settings are redirected to the selected system bus
node
7.
Carry out remote parameterisation for
more system bus nodes if required
Restart the process with step 1.
Do not forget to switch off remote parameterisation after completion of your settings:
8.
Select menu 3, "Remote para"
z y Z Y
Change to the "Remote para" menu using the arrow
keys
9.
Change to the code level
Z
Display of code C0370 "CANremot para"
10. Change to the parameter level
V
Display of the node address activated last, "Nodexx"
11. Switch off remote parameterisation
y
Set "0" = OFF