Technical data – Lenze E82xVxxxKxxxxx User Manual
Page 45
![background image](/manuals/566070/45/background.png)
Technical data
Operation with rated power (normal operation)
Rated data for 500 V mains voltage
l
45
EDS82EV903 EN 3.0
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
1.5
2.2
P
rated
[hp]
2.0
3.0
8200 vector type
EMC filter integrated
E82xV152K4C0xx
3)
E82xV222K4C0xx
3)
Without EMC filter
E82xV152K4C4xx
3)
E82xV222K4C2xx
3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke
I
mains
[A]
4.4
5.8
with mains choke
I
mains
[A]
3.1
4.1
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
1.1
0.4
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
3.1
4.5
4 kHz sin
8 kHz sin
I
r
[A]
3.1
4.5
16 kHz sin
2)
I
r
[A]
2.0
2.9
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
5.9
8.4
4 kHz sin
8 kHz sin
I
max
[A]
5.9
8.4
16 kHz sin
2)
I
max
[A]
3.0
4.4
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
100
130
E82DV... inside/outside
P
loss
[W]
33/67
43/87
E82CV... inside/cooler
P
loss
[W]
33/67
43/87
Dimensions
Dependent on the mounting variant (
^ 61)
Mass
E82EV...
m [kg]
1.6
E82DV...
m [kg]
1.6
E82CV...
m [kg]
1.1
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if
J reaches max. − 5 °C
3)
Operation with mains voltages 484 V − 0 % ... 550 V + 0 % only permissible with brake resistor!