4 dc braking (dcb), Dc braking (dcb), Function library – Lenze E82xVxxxKxxxxx User Manual
Page 292
![background image](/manuals/566070/292/background.png)
Function library
Acceleration, deceleration, braking, stopping
DC braking (DCB)
l
292
EDS82EV903 EN 3.0
10.6.4
DC braking (DCB)
Description
The DC−injection brake enables quick deceleration of the drive to standstill without using
an external brake resistor. The DC−injection brake can be activated via terminal or
automatically.
ƒ
The braking torque amounts to approx. 20 ... 30 % of the rated motor torque. It is
lower than for braking in generator mode with external brake resistor.
ƒ
A brake voltage or a brake current can be selected.
ƒ
Automatic DC braking improves the starting performance of the motor e.g. when
operating hoists.
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0019 Operating
threshold −
automatic DC
injection brake
(auto DCB)
0.10
0.00
= inactive
{0.02
Hz}
650.00 Hold time
ð C0106
Deactivate automatic DC injection
brake (auto DBC):
l
at active lower frequency
limitation (C0239)
l
at operating mode C0014 = 5
In the case of a max. output
frequency > 50 Hz (C0011), the
switching threshold of the auto
DCB in C0019 must be increased.
^ 292
C0035
*
v
Operation
mode − DC
injection brake
(DCB)
0
0
Brake voltage selection under C0036
Hold time
ð C0107
^ 292
1
Brake current selection under C0036
C0036 Voltage/
current DC
injection brake
(DCB)
а
0.00
{0.01 %}
150.00 %
а
Device−dependent
l
Based on V
rated
, I
rated
l
Setting applies to all permitted
mains voltages
^ 292
C0106 Hold time −
automatic DC
injection brake
(auto DCB)
0.50
0.00
= auto DCB
inactive
{0.01 s}
999.00
=
¥
Hold time if DC injection braking
is triggered because the value falls
below C0019
^ 292
C0107 Hold time − DC
injection brake
(DCB)
999.0
0
1.00
{0.01 s}
999.00
=
¥
Hold time if DC injection braking
is externally triggered via terminal
or control word
^ 292
C0196
*
v
Activation auto
DCB
0
0
Auto DCB active if PCTRL1−SET3 <
C0019
^ 292
1
Auto DCB active if PCTRL1−SET3 <
C0019 and NSET1−RFG1−IN < C0019