1 start conditions/flying-restart circuit, Start conditions/flying−restart circuit, Function library – Lenze E82xVxxxKxxxxx User Manual
Page 275
![background image](/manuals/566070/275/background.png)
Function library
Behaviour in the event of mains switching, mains failure or controller inhibit
Start conditions/flying−restart circuit
l
275
EDS82EV903 EN 3.0
10.4
Behaviour in the event of mains switching, mains failure or controller inhibit
10.4.1
Start conditions/flying−restart circuit
Description
Determines the controller behaviour after a restart after controller inhibit, mains
switching or a mains failure.
With activated flying−restart circuit the controller automatically synchronises to a
coasting motor after mains disconnection or adds a setpoint signal.
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0142
v
Starting
condition
1
0
Automatic start is inhibited after
mains connection
Flying restart circuit inactive
Start after HIGH−LOW−HIGH level
change at X3/28
^ 275
1
Automatic start if X3/28 = HIGH
Flying restart circuit inactive
2
Automatic start is inhibited after
mains connection
Flying restart circuit active
Start after HIGH−LOW−HIGH level
change at X3/28
3
Automatic start if X3/28 = HIGH
Flying restart circuit active
C0143
*
v
Selection of
flying restart
mode
0
0
Max. output frequency (C0011) ... 0 Hz
Motor speed is searched for in the
stated range
^ 275
1
Last output frequency ... 0 Hz
2
Connect frequency setpoint
(NSET1−NOUT)
The respective value is connected
after the controller enable
3
Connect actual process controller value
(C0412/5) (PCTRL1−ACT)
Drive behaviour without flying−restart circuit
Manual start (C0142 = 0):
After mains interruption the drive only restarts after a LOW/HIGH level change at the
"Controller inhibit" terminal (X3/28).
Automatic start (C0142 = 1)
After mains interruption the drive only restarts if a HIGH level is applied to the "controller
inhibit"terminal (X3/28).
The controller sets all integrators to zero and releases them again.
Drive behaviour with flying−restart circuit
Manual start with flying−restart circuit (C0142 = 2)
After mains interruption the drive only restarts after a LOW/HIGH level change at the
"Controller inhibit" terminal (X3/28).
Automatic start with flying−restart circuit (C0142 = 3)
After mains interruption the drive only restarts if a HIGH level is applied to the "controller
inhibit"terminal (X3/28).