Technical data
Operation with increased rated power
Rated data for a mains voltage of 230 V
l
52
EDS82EV903 EN 3.0
4.5.1
Rated data for a mains voltage of 230 V
Basis of the data
AC mains connection
1/N/PE
U
r
180 V − 0 % ... 264 V + 0 %; 45 Hz − 0 % ... 65 Hz + 0 %
3/PE
DC−mains connection
(alternatively)
U
DC
DC 260 V − 0 % ... 370 V + 0 %
Output voltage
With mains choke
V
M
3 ~ 0 ... approx. 94 % U
mains;
0 ... 650 Hz
without mains choke
V
M
3 ~ 0 ... U
mains;
0 ... 650 Hz
Periodic load change
60 s overcurrent with I
max
and 120 s base load with 75 % I
rated
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
0.37
0.75
P
rated
[hp]
0.5
1.0
8200 vector type
EMC filter integrated
E82xV251K2C0xx
E82xV551K2C0xx
2)
Without EMC filter
E82xV251K2C2xx
E82xV551K2C2xx
2)
Mains
1/N/PE
1/N/PE
3/PE
Rated mains current
without mains choke
I
mains
[A]
4.1
−
−
with mains choke
I
mains
[A]
3.6
6.7
3.3
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
−
−
0.1
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
2.0
3.6
4 kHz sin
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
2.5
4.5
4 kHz sin
Power loss (operation with
I
N24
)
E82EV...
P
loss
[W]
30
50
E82DV... inside/outside
P
loss
[W]
10/20
17/33
E82CV... inside/cooler
P
loss
[W]
10/20
17/33
Dimensions
Dependent on the mounting variant (
^ 61)
Mass
E82EV...
m [kg]
0.8
1.2
E82DV...
m [kg]
0.8
1.2
E82CV...
m [kg]
0.6
0.9
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Operation only permitted with mains choke (
^ 106)