Application examples – Lenze E82xVxxxKxxxxx User Manual

Page 509

Advertising
background image

Application examples

Speed control

15

l

509

EDS82EV903 EN 3.0

Speed sensor requirements

)

Note!

You can use every speed sensor which meets the level and scanning ratio
requirements.

ƒ

The maximum frequency of inductive sensors generally ranges from 1 ... 6 kHz
depending on the type.

ƒ

At the detection point, the number of attenuation cams per revolution must ensure
an output frequency of the sensor as high as possible.

ƒ

The control dynamics will be sufficient if the output frequency (f

act

) is > 0.5 kHz at

rated speed.

ƒ

If the current consumption of the sensor is not higher than the value permitted at
X3/20, a three−wire sensor can be directly connected to the controller.

Output frequency calculation

f

ist+

z @ n

60

z = number of cams per revolution
n = speed at the detection point [rpm]
f

act

= output frequency of the sensor in [Hz]

Permissible pulse shape at X3/E1

T ³ 1 0 0 m s

T e

T a

1 5 V

U

E 1

t

0

0

l

T

e

= on (HIGH)

l

T

a

= off (LOW)

Permissible level range:

l

LOW: 0 ... +3 V

l

HIGH: +12 ... +30 V

Permissible range of the scanning ratio

l

T

e

: T

a

= 1 : 1 until T

e

: T

a

= 1 : 5

Advertising