Braking operation

Braking operation with external brake resistor

8200 vector 0.25 ... 11 kW

13

l

485

EDS82EV903 EN 3.0

Integrated brake chopper 8200 vector 0.25 ... 7.5 kW / 230 V

Brake chopper

8200 vector, 230 V

E82xV251K2C

E82xV371K2C

E82xV551K2C

E82xV751K2C

E82xV152K2C

E82xV222K2C

Switching threshold
V

DC

[V DC]

380 (fixed)

Peak current for
0.5 s

[A DC]

1

4

9

Max. continuous
current

[A DC]

1

2

6

Peak braking power

[kW]

0.3

1.5

3.3

Max. continuous
power

[kW]

0.3

0.8

2.2

Min. brake
resistance
(V

DC

= 380 V)

[

W]

470

90

47

Current derating

40 ... 55 °C: derate peak braking current by 2.5 %/°C

1000 ... 4000 m amsl: derate peak braking current by 5 %/1000 m

Switch−on cycle

Max. 60 s with peak braking current, then at least 60 s recovery time

Recommended
Lenze brake resistor

Type

ERBM470R020W

ERBM200R100W

ERBM

082R150W

ERBM

052R200W

Brake chopper

8200 vector, 230 V

E82xV302K2C

E82xV402K2C

E82xV552K2C

E82xV752K2C

Switching threshold
V

DC

[V DC]

380 (fixed)

Peak current for
0.5 s

[A DC]

13

13

20

20

Max. continuous
current

[A DC]

8

11

15

20

Peak braking power

[kW]

4.9

4.9

7.6

7.6

Max. continuous
power

[kW]

3.0

4.1

5.6

7.6

Min. brake
resistance
(V

DC

= 380 V)

[

W]

29

19

Current derating

40 ... 55 °C: derate peak braking current by 2.5 %/°C

1000 ... 4000 m amsl: derate peak braking current by 5 %/1000 m

Switch−on cycle

Max. 60 s with peak braking current, then at least 60 s recovery time

Recommended
Lenze brake resistor

Type

ERBD047R01K2

ERBD047R01K2

ERBD047R01K2

ERBD047R01K2