Function library

Parameter set management
Saving and copying parameter sets

10

l

368

EDS82EV903 EN 3.0

10.16

Parameter set management

10.16.1

Saving and copying parameter sets

Description

Management of the controller parameter sets. It is possible to

ƒ

restore the Lenze setting and put the controller into the delivery state again.

ƒ

save your own basic setting, e.g. the delivery state of the machine.

ƒ

transfer parameter sets from the keypad to the controller or vice versa. The settings
can thus be easily copied between controllers.

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0002
*

s

uSEr

Parameter set
management

0

0

Ready

PAR1 ... PAR4:

l

Parameter sets of the controller

l

PAR1 ... PAR4 also contain the
parameters for the function
modules standard I/O,
application I/O, AS interface,
system bus (CAN)

FPAR1:

l

Module−specific parameter set
of the fieldbus function
modules INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

l

FPAR1 is saved in the function
module

^ 368

Restoring the
delivery status

1

Lenze setting

ð PAR1

Restore the delivery status in the
parameter set selected

2

Lenze setting

ð PAR2

3

Lenze setting

ð PAR3

4

Lenze setting

ð PAR4

31

Lenze setting

ð FPAR1

Restore the delivery status in the
fieldbus function module

61

Lenze setting

ð PAR1 + FPAR1

Restore the delivery status in the
selected parameter set of the
controller and in the fieldbus
function module

62

Lenze setting

ð PAR2 + FPAR1

63

Lenze setting

ð PAR3 + FPAR1

64

Lenze setting

ð PAR4 + FPAR1

C0002
*

s

uSEr

(Continu
ation)

Transferring
parameter sets
with the
keypad

By means of the keypad you can
transfer the parameter sets to
other controllers.
During the transmission the access
to the parameters via other
channels is inhibited!

Keypad

ð controller

Overwrite all available parameter
sets (PAR1 ... PAR4, if required
FPAR1) with the corresponding
data of the keypad

70

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen

10

with all other function modules