2 free configuration of digital outputs, Function library – Lenze E82xVxxxKxxxxx User Manual

Page 348

Advertising
background image

Function library

Free interconnection of digital signals
Free configuration of digital outputs

10

l

348

EDS82EV903 EN 3.0

10.12.2

Free configuration of digital outputs

Description

ƒ

The digital outputs (X3/A1, X3/A2, relay output K1, relay output K2) can be freely
assigned to internal digital signals.

ƒ

A signal source can be assigned to several targets.

)

Note!

ƒ

Use C0008 to assign some internal signal sources to the relay output D1.
C0415/1 is automatically adapted.

ƒ

Use C0117 to assign some internal signal sources to the digital output
X3/A1. C0415/2 is automatically adapted.

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0415

v

Free
configuration
of digital
outputs

Output of digital signals to terminals

^ 348

1 Relay output

K1 (RELAY,
motec version
151:)
Digital
switching
output K1
(motec version
152, 153)

25

TRIP error message (DCTRL1−TRIP)

A selection in C0008 is copied into
C0415/1. Change of C0415/1 sets
C0008 = 255!

2 Digital output

X3/A1
(DIGOUT1)

16

Ready for operation (DCTRL1−RDY)

A selection in C0117 is copied into
C0415/2. Change of C0415/2 sets
C0117 = 255!

3

(A)

Digital output
X3/A2
(DIGOUT2)

255

Not assigned (FIXED−FREE)

Advertising