Extensions for automation

Standard devices in a power range from 3 ... 11 kW
Combine function and communication modules

7

l

174

EDS82EV903 EN 3.0

7.2.4

Combine function and communication modules

Possible combinations

Function module on FIF

Communication module on AIF

Keypad E82ZBC

Keypad XT

EMZ9371BC

PROFIBUS−DP

EMF2133IB

System bus

CAN

EMF2171IB
EMF2172IB

CANopen

EMF2178IB

DeviceNet

EMF2179IB

Ethernet

PowerLink

EMF2191IB

Standard I/O PT

E82ZAFSC010

ь

ь

ь

ь

ь

ь

Application I/O PT

E82ZAFAC010

ь

ь

)

ь

)

ь

)

ь

)

ь

)

PROFIBUS−DP

E82ZAFPC010

ü

x

x

x

x

x

PROFIBUS I/O

E82ZAFPC201

Sys. bus CAN PT

E82ZAFCC010

ь

ь

ь

ь

ь

ь

Sys. bus CAN PT

E82ZAFCC210

Sys.−bus CAN−I/O RS PT

E82ZAFCC100

CANopen PT

E82ZAFUC010

ü

x

x

x

x

x

DeviceNet PT

E82ZAFVC010

ü

x

x

x

x

x

INTERBUS PT

E82ZAFIC010

ü

x

x

x

x

x

LECOM−B PT

E82ZAFLC010

ü

x

x

x

x

x

AS interface PT

E82ZAFFC010

ü

x

x

x

x

x

Function module on FIF

Communication module on AIF

INTERBUS

EMF2113IB

LECOM−A/B

EMF2102IBC V001

LECOM−A

EMF2102IBC V004

LECOM−B

EMF2102IBC V002

LECOM−LI

EMF2102IBC V003

Standard I/O PT

E82ZAFSC010

ь

ь

ь

ь

ь

Application I/O PT

E82ZAFAC010

ь

)

ь

)

ь

)

ь

)

ь

)

PROFIBUS−DP

E82ZAFPC010

x

ь

)

ь

ь

)

ь

)

PROFIBUS I/O

E82ZAFPC201

Sys. bus CAN PT

E82ZAFCC010

ь

ь

ь

ь

ь

Sys. bus CAN PT

E82ZAFCC210

Sys.−bus CAN−I/O RS PT

E82ZAFCC100

CANopen PT

E82ZAFUC010

x

ь

)

ь

ь

)

ь

)

DeviceNet PT

E82ZAFVC010

x

ь

)

ь

ь

)

ь

)

INTERBUS PT

E82ZAFIC010

x

ь

)

ь

ь

)

ь

)

LECOM−B PT

E82ZAFLC010

x

ь

)

ь

ь

)

ь

)

AS interface PT

E82ZAFFC010

x

ь

)

ь

ь

)

ь

)

ь

Combination possible, communication module can be supplied internally or externally
(keypad only internally)

ü

Combination possible, communication module has to be supplied externally

x

Combination not possible

7.2.5

Mounting and dismounting function modules

{

Danger!

Dangerous electrical voltage
During operation of the standard device and up to 3 minutes after power−off
dangerous electrical voltages may be applied at the power terminals.
Possible consequences:

ƒ

Death or severe injuries when touching the terminals.

Protective measures:

ƒ

Disconnect the standard device from the mains and wait for 3 minutes
before you start working.

ƒ

Check all power terminals for isolation from supply.

Advertising