Parameter setting – Lenze E82xVxxxKxxxxx User Manual
Page 230
![background image](/manuals/566070/230/background.png)
Parameter setting
Parameter setting with E82ZBC keypad
Transferring parameters to other standard devices
l
230
EDS82EV903 EN 3.0
Copy parameter set from the keypad to the standard device
Step
Key seq.
Result
Action
1. Connect the keypad to standard
device 2
g
xx.xx
Hz
Function
g is active. The first code in the user
menu (C0517/1, Lenze setting: C0050 = output
frequency) is displayed.
2. Inhibit controller
s
dc
The drive is coasting.
3. Select C0002 from the user menu
x
f
4.
z
0002
Select C0002
5.
x
i
6. Select the correct copy function
The settings stored in the standard device or in
the function module are overwritten.
l
Copy all available parameter sets (PAR1 ... PAR4, if required FPAR1) into the standard device:
– Standard device with function
module application I/O, AS
interface,
INTERBUS, PROFIBUS, LECOM−B,
DeviceNet, CANopen
z
70
Copy PAR1 ... PAR4 and FPAR1:
ð Set "70"
– Standard device with all other
function modules
z
10
Copy PAR1 ... PAR4:
ð Set "10"
l
Only copy the module−specific parameter set FPAR1 into the function module:
– Only possible with standard
devices including function
module INTERBUS,
PROFIBUS, LECOM−B, DeviceNet,
CANopen
z
40
Copy FPAR1:
ð Set "40"
l
Copy individual parameter sets (PARx and FPAR1 if available) to the standard device:
– Standard device with function
module application I/O,
INTERBUS,
PROFIBUS, LECOM−B, DeviceNet,
CANopen
z
71
Copy PAR1 and FPAR1:
ð Set "71"
z
72
Copy PAR2 and FPAR1:
ð Set "72"
z
73
Copy PAR3 and FPAR1:
ð Set "73"
z
74
Copy PAR4 and FPAR1:
ð Set "74"
– Standard device with all other
function modules
z
11
Copy PAR1:
ð Set "11"
z
12
Copy PAR2:
ð Set "12"
z
13
Copy PAR3:
ð Set "13"
z
14
Copy PAR4:
ð Set "14"
7. Start copying
v
STOre
or
load
The selected parameter sets are copied to the
standard device or to the function module.
If STOrE or load goes off, the copy process is
complete.
8. Enable controller
u
The drive operates again.