Technical data – Lenze E82xVxxxKxxxxx User Manual

Page 43

Advertising
background image

Technical data

Operation with rated power (normal operation)

Rated data for 400 V mains voltage

4

l

43

EDS82EV903 EN 3.0

Typical motor power −
three−phase asynchronous
motor (4−pole)

P

rated

[kW]

75

90

P

rated

[hp]

100

125

8200 vector type

With mains filter

E82xV753K4B3xx

E82xV903K4B3xx

Without mains filter

E82xV753K4B2xx

3)

E82xV903K4B2xx

3)

Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)

without mains choke/mains

filter

I

mains

[A]

With mains choke/mains filter

I

mains

[A]

135

165

Output power +U

DC

, −U

DC

1)

P

DCres

[kW]

28.1

40.8

Rated output
current at
switching
frequency

1 kHz sin

I

r

[A]

150

159

4)

2 kHz sin

4 kHz sin

8 kHz sin

I

r

[A]

92

4)

100

4)

16 kHz sin

2)

I

r

[A]

67

72

1 kHz

I

r

[A]

150

180

2 kHz

4 kHz

8 kHz

I

r

[A]

150

171

16 kHz

2)

I

r

[A]

105

108

Max. permissible
output current for
60 s at switching
frequency

1 kHz sin

I

max

[A]

225

238

4)

2 kHz sin

4 kHz sin

8 kHz sin

I

max

[A]

138

4)

150

4)

16 kHz sin

2)

I

max

[A]

87

94

1 kHz

I

max

[A]

225

270

2 kHz

4 kHz

8 kHz

I

max

[A]

225

221

16 kHz

2)

I

max

[A]

136

140

Power loss (operation with I

N8

)

E82EV...

P

loss

[W]

1960

2400

E82DV... inside/outside

P

loss

[W]

653/1307

800/1600

E82CV... inside/cooler

P

loss

[W]

Dimensions

Dependent on the mounting variant (

^ 61)

Mass with mains
filter

E82EV...

m [kg]

112

E82DV...

m [kg]

112

E82CV...

m [kg]

Mass without
mains filter

E82EV...

m [kg]

59

E82DV...

m [kg]

59

E82CV...

m [kg]

1)

Power supplied by the DC bus when operating with power−adapted motor

2)

Switching frequency is reduced to 4 kHz if

J reaches max. − 5 °C

3)

Operation only permitted with mains choke (

^ 106)

4)

Only operate with automatic switching frequency reduction (C144 = 1). Ensure that the specified current values are
not exceeded.