Technical data – Lenze E82xVxxxKxxxxx User Manual
Page 43
![background image](/manuals/566070/43/background.png)
Technical data
Operation with rated power (normal operation)
Rated data for 400 V mains voltage
l
43
EDS82EV903 EN 3.0
Typical motor power −
three−phase asynchronous
motor (4−pole)
P
rated
[kW]
75
90
P
rated
[hp]
100
125
8200 vector type
With mains filter
E82xV753K4B3xx
E82xV903K4B3xx
Without mains filter
E82xV753K4B2xx
3)
E82xV903K4B2xx
3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke/mains
filter
I
mains
[A]
−
−
With mains choke/mains filter
I
mains
[A]
135
165
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
28.1
40.8
Rated output
current at
switching
frequency
1 kHz sin
I
r
[A]
150
159
4)
2 kHz sin
4 kHz sin
8 kHz sin
I
r
[A]
92
4)
100
4)
16 kHz sin
2)
I
r
[A]
67
72
1 kHz
I
r
[A]
150
180
2 kHz
4 kHz
8 kHz
I
r
[A]
150
171
16 kHz
2)
I
r
[A]
105
108
Max. permissible
output current for
60 s at switching
frequency
1 kHz sin
I
max
[A]
225
238
4)
2 kHz sin
4 kHz sin
8 kHz sin
I
max
[A]
138
4)
150
4)
16 kHz sin
2)
I
max
[A]
87
94
1 kHz
I
max
[A]
225
270
2 kHz
4 kHz
8 kHz
I
max
[A]
225
221
16 kHz
2)
I
max
[A]
136
140
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
1960
2400
E82DV... inside/outside
P
loss
[W]
653/1307
800/1600
E82CV... inside/cooler
P
loss
[W]
−
−
Dimensions
Dependent on the mounting variant (
^ 61)
Mass with mains
filter
E82EV...
m [kg]
112
E82DV...
m [kg]
112
E82CV...
m [kg]
−
Mass without
mains filter
E82EV...
m [kg]
59
E82DV...
m [kg]
59
E82CV...
m [kg]
−
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if
J reaches max. − 5 °C
3)
Operation only permitted with mains choke (
^ 106)
4)
Only operate with automatic switching frequency reduction (C144 = 1). Ensure that the specified current values are