2 diagnostics, Function library – Lenze E82xVxxxKxxxxx User Manual

Page 366

Advertising
background image

Function library

Display of operating data, diagnostics
Diagnostics

10

l

366

EDS82EV903 EN 3.0

10.15.2

Diagnostics

Description

Display codes for diagnostics

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0093
*

Device type

xxxy

Read only

l

xxx = performance data from
the type code (e.g. 551 = 550
W)

l

y = voltage class (2 = 240 V,
4 = 400 V)

C0099
*

Software
version

x.y

Read only
x = major version, y = index

C0161
*

Active fault

Display of history buffer contents

l

Keypad: three−digit
alphanumeric fault
identification

l

Operating module 9371BB:
LECOM error number

^ 453

C0162
*

Last fault

C0163
*

Last fault but
one

C0164
*

Last fault but
two

C0168
*

Pending error

Display of history buffer "Active
fault"

l

Keypad: three−digit
alphanumeric fault
identification

l

Operating module 9371BB:
LECOM error number

^ 453

C0179
*

Power−on time

{h}

Read only
Total time of mains "ON"

C0183
*

Diagnostics

0

No fault

Read only

102

TRIP active

104

Message "Overvoltage (OU)" or
"Undervoltage (LU)" active

142

Pulse inhibit

151

Quick stop is active

161

DC injection brake active

250

Warning active

C0200
*

Software ID

Read only on PC
x = main version, y = subversion

82S8212V_xy000

8200 vector 0.25 ... 11 kW

82S8212V_xy010

8200 vector 15 ... 90 kW

C0201
*

Software
creation date

Read only on PC

C0202
*

Software ID

Output in keypad as string in four parts at four
characters each

Read only in keypad

1

82S8

2

212 V

3

_xy0

x = main version, y = subversion

4

zz

00 = 8200 vector 0.25 ... 11 kW
10 = 8200 vector 15 ... 90 kW

Advertising