Function library

Code table

10

l

408

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0323
(A)

Ramp function
generator
input (NSET1−
RFG1−IN)

−650.00

{0.02

Hz}

650.00 Read only

C0324
(A)

Ramp function
generator
output (NSET1−
NOUT)

−650.00

{0.02

Hz}

650.00 Read only

C0325
(A)

PID controller
output
(PCTRL1−PID−
OUT)

−650.00

{0.02

Hz}

650.00 Read only

C0326
(A)

Process
controller
output
(PCTRL1−NOUT)

−650.00

{0.02

Hz}

650.00 Read only

C0350
*

v

System bus
node address

1

1

{1}

63

l

Only for system bus function
module E82ZAFCC on the FIF
interface.

l

Change becomes effective
after "Reset−Node" command

Set the node address in C0009 for
operation with communication
modules 217x.

^ 375

C0351
*

v

System bus
baud rate

0

0

500 kbps

l

Only for system bus function
module E82ZAFCC on the FIF
interface.

l

Change becomes effective
after "Reset−Node" command

Set the baud rate in C0125 for
operation with communication
modules 217x.

^ 375

1

250 kbps

2

125 kbps

3

50 kbps

4

1000 kbps (function module
E82ZAFCC100 only)

5

20 kbps

C0352
*

v

Configuration
of system bus
node

0

0

Slave

l

Only for system bus function
module E82ZAFCC on the FIF
interface.

l

Change becomes effective
after "Reset−Node" command

^ 375

1

Master

C0353
*

v

System bus
address source

l

Only for system bus function
module E82ZAFCC on the FIF
interface.

l

Source of address for system
bus process data channels

^ 375

1 CAN1 (Sync)

0

0

C0350 is the source

Effective with sync control (C0360
= 1)

2 CAN2

0

1

C0354 is the source

3 CAN1 (time)

0

Effective with event or time
control (C0360 = 0)

C0354
*

v

Selective
system bus
address

0

{1}

513

l

Only for system bus function
module E82ZAFCC on the FIF
interface.

l

Single addressing of system
bus process data objects

^ 375

1 CAN−IN1 (sync)

129

Effective with sync control (C0360
= 1)

2 CAN−OUT1

(sync)

1

3 CAN−IN2

257

4 CAN−OUT2

258

5 CAN−IN1 (time)

385

Effective with event or time
control (C0360 = 0)

6 CAN−OUT1

(time)

386