Function library, Code table – Lenze E82xVxxxKxxxxx User Manual
Page 408
![background image](/manuals/566070/408/background.png)
Function library
Code table
l
408
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0323
(A)
Ramp function
generator
input (NSET1−
RFG1−IN)
−650.00
{0.02
Hz}
650.00 Read only
C0324
(A)
Ramp function
generator
output (NSET1−
NOUT)
−650.00
{0.02
Hz}
650.00 Read only
C0325
(A)
PID controller
output
(PCTRL1−PID−
OUT)
−650.00
{0.02
Hz}
650.00 Read only
C0326
(A)
Process
controller
output
(PCTRL1−NOUT)
−650.00
{0.02
Hz}
650.00 Read only
C0350
*
v
System bus
node address
1
1
{1}
63
l
Only for system bus function
module E82ZAFCC on the FIF
interface.
l
Change becomes effective
after "Reset−Node" command
Set the node address in C0009 for
operation with communication
modules 217x.
^ 375
C0351
*
v
System bus
baud rate
0
0
500 kbps
l
Only for system bus function
module E82ZAFCC on the FIF
interface.
l
Change becomes effective
after "Reset−Node" command
Set the baud rate in C0125 for
operation with communication
modules 217x.
^ 375
1
250 kbps
2
125 kbps
3
50 kbps
4
1000 kbps (function module
E82ZAFCC100 only)
5
20 kbps
C0352
*
v
Configuration
of system bus
node
0
0
Slave
l
Only for system bus function
module E82ZAFCC on the FIF
interface.
l
Change becomes effective
after "Reset−Node" command
^ 375
1
Master
C0353
*
v
System bus
address source
l
Only for system bus function
module E82ZAFCC on the FIF
interface.
l
Source of address for system
bus process data channels
^ 375
1 CAN1 (Sync)
0
0
C0350 is the source
Effective with sync control (C0360
= 1)
2 CAN2
0
1
C0354 is the source
3 CAN1 (time)
0
Effective with event or time
control (C0360 = 0)
C0354
*
v
Selective
system bus
address
0
{1}
513
l
Only for system bus function
module E82ZAFCC on the FIF
interface.
l
Single addressing of system
bus process data objects
^ 375
1 CAN−IN1 (sync)
129
Effective with sync control (C0360
= 1)
2 CAN−OUT1
(sync)
1
3 CAN−IN2
257
4 CAN−OUT2
258
5 CAN−IN1 (time)
385
Effective with event or time
control (C0360 = 0)
6 CAN−OUT1
(time)
386