Function library – Lenze E82xVxxxKxxxxx User Manual

Page 290

Advertising
background image

Function library

Acceleration, deceleration, braking, stopping
Quick stop

10

l

290

EDS82EV903 EN 3.0

Activation

Via digital signal:

Link C0410/4 to a digital signal source.

ƒ

LOW level at signal source activates quick stop

ƒ

Level inversion possible with C0411

)

Note!

Quick stop can also be activated if the "Fail−safe changeover of the direction of
rotation" function is used. (

291)

In addition to the free configuration in C0410 you can also use the fixed
assignment in C0007 to link the function with a digital input.

Via keyboard of the keypad:

For this purpose, assign the quick stop function to the key:

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0469
*

s

Function of the

s key of the
keypad

1

0

Stop key without function

Determines the function to be
executed when the stop key is
pressed

l

s activates quick stop

l

U restarts the drive

Changes are only active after
mains connection!

1

CINH (controller inhibit)

2

QSP (quick stop)

Advertising