5 controller with communication module, Controller with communication module, Signalflusspläne – Lenze E82xVxxxKxxxxx User Manual
Page 521
Signalflusspläne
Signal processing − overview
Controller with communication module
l
521
EDS82EV903 EN 3.0
16.2.5
Controller with communication module
AIF-IN
AIFCTRL.B0
AIFCTRL.B1
AIFCTRL.B2
AIFCTRL.B3
AIFCTRL.B4
AIFCTRL.B8
CINH
TRIP-SET
TRIP-RESET
AIFCTRL.B12
AIFCTRL.B15
DCTRL
16
Bit
16
Bit
AIF-CTRL
Byte3,4
Byte5,6
AIFCTRL.B9
AIFCTRL.B10
AIFCTRL.B1
1
QSP
DCTRL
AIF-IN1.W2
AIF-IN1.W1
AIF
1
1
1
1
1
1
1
DIGIN2
C01
19
X2.2
1,4
0,3
T1
T2
2,5
W
ARN
TRIP
1
1
0
1
C041
1
2
2
2
2
2
2
2
2
1
1
2
2
NSET1
NSET1-RFG1-ST
OP
NSET1-RFG1-0
NSET1-N1
NSET1-JOG1/3
NSET1-JOG2/3
NSET1-RFG1-I=0
NSET1-RFG1-IN
NSET1-N2
NSET1-NOUT
C0412/1
C0412/2
C0410/1
C0410/2
C0410/5
C0410/6
1
1
1
1
1
1
1
2
2
2
PCTRL1
2
2
2
PCTRL1-I-OFF
PCTRL1-ACT
PCTRL1-SET1
PCTRL1-OFF
PCTRL1-ST
OP
PCTRL1-OUT
PCTRL1-SET=ACT
PCTRL1-SET
PCTRL1-ACT
PCTRL1-QMIN
PCTRL1-NMIN
PCTRL1-NADD
C0412/3
C0410/21
C0412/4
C0412/5
C0410/18
C0410/19
PCTRL1-NOUT
PCTRL1-SET3
1
1
1
1
1
1
1
1
1
2
2
2
2
2
MPOT1
MPOT1-OUT
C0265
2
C0410/7
MPOT1-UP
C0410/8
MPOT1-DOWN
MPOT1-QSP
C001
1
C0010
C0265=3,4,5
MPOT INIT
1
1
DCTRL1-TRIP-SET
DCTRL1-TRIP-RESET
DCTRL1-P
AR
2/4
DCTRL1-P
AR
3/4
DCTRL1-CW/QSP
DCTRL1
DCTRL1-P
AR-B0
DCTRL1-P
AR-B1
DCTRL1-CINH
DCTRL1-OH-W
ARN
DCTRL1-OV
DCTRL1-RDY
DCTRL1-TRIP-QMIN-IMP
DCTRL1-PTC-W
ARN
DCTRL1-LP1-W
ARN
DCTRL1-TRIP
DCTRL1-IMP
DCTRL1-IMOT<ILIM
DCTRL1-(IMOT<ILIM)-QMIN
DCTRL1-(IMOT<ILIM)-RFG-I=O
DCTRL1-(IMOT>ILIM)-RFG-I=O
DCTRL1-RFG1=NOUT
DCTRL1-NOUT=0
DCTRL1-RUN
DCTRL1-RUN-CW
DCTRL1-RUN-CCW
DCTRL1-CCW
DCTRL1-CW/CCW
DCTRL1-QSP
DCTRL1-H/Re
DCTRL1-CCW/QSP
C0410/22
C0410/1
1
C0410/12
C0410/13
C0410/14
C0410/3
C0410/4
C0410/17
C0410/23
DCTRL1-C0010...C001
1
DCTRL1-OH-PCT
-LP1-F
AN-W
ARN
DCTRL1-CINH
C0410/10
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
AIF-OUT
AIFST
AT
.B0
AIFST
AT
.B15
C0421/1
AIF-OUT
.W1
C0421/2
AIF-OUT
.W2
2
2
16
Bit
16
Bit
AIF-STAT
Byte3,4
Byte5,6
AIF
...
ST
AT1.B15
ST
AT1.B0
…
S
TAT
1
C0417/16
C0417/1
…
…
2
2 2
RELA
Y
1
C0416
K14
1
1
0
C0415/1
K1
1
K12
X1.2
2
RELA
Y
2
8200
vector
15
...
90kW
K21
1
1
0
C0409
K22
K24
X1.3
C0416
2
MCTRL1-VOL
T-ADD
MCTRL1-DCB
MCTRL1-PHI-ADD
MCTRL1-NOUT+SLIP
MCTRL1-NOUT
MCTRL1-NOUT
-NORM
MCTRL1-Imax
MCTRL1-MSET=MACT
MCTRL1-VOL
T
MCTRL1-IMOT
MCTRL1-DCVOL
T
MCTRL1-MOUT
MCTRL1-1/NOUT
MCTRL1-MACT
C0412/6
C0410/15
C0412/8
C0412/9
MCTRL1-MSET
MCTRL1
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
2
2
2
2
8200vec500
Fig. 16−5
Overview of signal flow with communication module