Parameter setting – Lenze E82xVxxxKxxxxx User Manual

Page 233

Advertising
background image

Parameter setting

Parameter setting with E82ZBC keypad

Remote parameter setting for system bus participants

9

l

233

EDS82EV903 EN 3.0

9.2.7

Remote parameter setting for system bus participants

If controllers are linked via the system bus (CAN), remote parameterisation of all other
nodes of the system bus is possible from a central point in the network.

For this purpose, use the

n function.

)

Note!

Instead of using the

nfunction, the system bus node can also be selected via

C0370.

Step

Key seq.

Result

Action

1.

Select function

t



Change to function bar 2

2.

wx

n

3.

Select node
address

yz

1 ... 63

Select node address

4.

t

Œ

r

Confirm address and change to function bar 1
Now remote parameterisation can be carried out for the node.

5.

Set
parameters

All settings are redirected to the selected node.

6.

Carry out
remote
parameterisati
on for more
system bus
nodes if
required

Restart the process with step 1.

Do not forget to switch off remote parameterisation after completion of your settings:

7.

Switch off
remote
parameterisati
on

t



Change to function bar 2

8.

wx

n

9.

y

0

Switch off remote parameterisation

10.

t

Œ

Confirm and change to function bar 1

Remote parameterisation is completed.