Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Menu structure
l
250
EDS82EV903 EN 3.0
Description
Submenus
Main menu
Description
Display
No.
Display
No.
5.26
PID−Ctrl 5
Operation with the system bus (CAN) function module on FIF
Setpoint via process data channel (CAN−IN1.W2)
Actual value via process data channel (CAN−IN1.W3)
5.26.1 CAN managem System bus (CAN) communication set−up
5.26.2 Setpoint
Setpoint configuration
5.26.3 Actual value
Actual value configuration
5.26.4 PCTRL setup
Process controller configuration
5.26.5 f limit/ramp
Output frequency, acceleration time and deceleration time
configuration
5.26.6 Motor param
Motor current control configuration, motor monitoring
5.27
PID−Ctrl 7
Operation with fieldbus function module on FIF (DRIVECOM
control)
Frequency setpoint via process data channel
Actual frequency value via process data channel
5.27.1 FIF managem
Fieldbus communication set−up
5.27.2 Setpoint
Setpoint configuration
5.27.3 Actual value
Actual value configuration
5.27.4 PCTRL setup
Process controller configuration
5.27.5 f limit/ramp
Output frequency, acceleration time and deceleration time
configuration
5.27.6 Motor param
Motor current control configuration, motor monitoring
6
Diagnostics
Diagnostics
6.1
Fault history
Fault analysis with history buffer
6.2
Status words
Display of status words
6.3
Monit drive
Display codes to monitor the drive
6.4
Monit FIF
Display codes for monitoring a fieldbus function module
7
Param
managm
Parameter set management
7.1
Load / Store
Parameter set transfer, restore delivery status
7.2
Copy PAR1 −>2
Copy parameter set 1 to parameter set 2
7.3
Copy PAR1 −>3
Copy parameter set 1 to parameter set 3
7.4
Copy PAR1 −>4
Copy parameter set 1 to parameter set 4
8
Main FB
Configuration of function blocks
8.1
Cfg NSET1
Setpoint processing
8.2
Cfg PCTRL1
Process controller
8.3
Cfg DCTRL1
Internal control
8.4
Cfg MCTRL1
Motor control
9
Controller
Configuration of internal control parameters
9.1
V/f−Ctrl
V/f characteristic control
9.2
Vector−Ctrl
Vector control
9.3
PCTRL setpt
Process controller setpoints
9.4
PCTRL act val
Actual process controller values
9.5
PCTRL setup
Process control
9.6
Current setup
Current limits and current controllers
9.7
Setpt setup
Setpoints
9.8
Ramp times
Acceleration times, deceleration times
9.9
DCB (DC brk)
DC injection brake
9.10
Fault monit
Fault monitoring, fault display