Parameter setting

Parameter setting with the XT EMZ9371BC keypad
Menu structure

9

l

250

EDS82EV903 EN 3.0

Description

Submenus

Main menu

Description

Display

No.

Display

No.

5.26

PID−Ctrl 5

Operation with the system bus (CAN) function module on FIF
Setpoint via process data channel (CAN−IN1.W2)
Actual value via process data channel (CAN−IN1.W3)

5.26.1 CAN managem System bus (CAN) communication set−up

5.26.2 Setpoint

Setpoint configuration

5.26.3 Actual value

Actual value configuration

5.26.4 PCTRL setup

Process controller configuration

5.26.5 f limit/ramp

Output frequency, acceleration time and deceleration time
configuration

5.26.6 Motor param

Motor current control configuration, motor monitoring

5.27

PID−Ctrl 7

Operation with fieldbus function module on FIF (DRIVECOM
control)
Frequency setpoint via process data channel
Actual frequency value via process data channel

5.27.1 FIF managem

Fieldbus communication set−up

5.27.2 Setpoint

Setpoint configuration

5.27.3 Actual value

Actual value configuration

5.27.4 PCTRL setup

Process controller configuration

5.27.5 f limit/ramp

Output frequency, acceleration time and deceleration time
configuration

5.27.6 Motor param

Motor current control configuration, motor monitoring

6

Diagnostics

Diagnostics

6.1

Fault history

Fault analysis with history buffer

6.2

Status words

Display of status words

6.3

Monit drive

Display codes to monitor the drive

6.4

Monit FIF

Display codes for monitoring a fieldbus function module

7

Param
managm

Parameter set management

7.1

Load / Store

Parameter set transfer, restore delivery status

7.2

Copy PAR1 −>2

Copy parameter set 1 to parameter set 2

7.3

Copy PAR1 −>3

Copy parameter set 1 to parameter set 3

7.4

Copy PAR1 −>4

Copy parameter set 1 to parameter set 4

8

Main FB

Configuration of function blocks

8.1

Cfg NSET1

Setpoint processing

8.2

Cfg PCTRL1

Process controller

8.3

Cfg DCTRL1

Internal control

8.4

Cfg MCTRL1

Motor control

9

Controller

Configuration of internal control parameters

9.1

V/f−Ctrl

V/f characteristic control

9.2

Vector−Ctrl

Vector control

9.3

PCTRL setpt

Process controller setpoints

9.4

PCTRL act val

Actual process controller values

9.5

PCTRL setup

Process control

9.6

Current setup

Current limits and current controllers

9.7

Setpt setup

Setpoints

9.8

Ramp times

Acceleration times, deceleration times

9.9

DCB (DC brk)

DC injection brake

9.10

Fault monit

Fault monitoring, fault display