Function library – Lenze E82xVxxxKxxxxx User Manual
Page 259
![background image](/manuals/566070/259/background.png)
Function library
Operating mode
V/f characteristic control
l
259
EDS82EV903 EN 3.0
Typical values for C0015
400 V controller E82xVxxxK4C
230 V controller E82xVxxxK2C
Motor
C0015
Motor
C0015
Voltage
Frequency
Connection
Voltage
Frequency
Connection
230/400 V
50 Hz
*
50 Hz
230/400 V
50 Hz
F
50 Hz
220/380 V
50 Hz
*
52.6 Hz
220/380 V
50 Hz
F
52.3 Hz
280/480 V
60 Hz
*
50 Hz
400/690 V
400 V
50 Hz
50 Hz
F
50 Hz
230/400 V
280/480 V
400 V
50 Hz
60 Hz
87 Hz
F
87 Hz
220/380 V
50 Hz
F
90.9 Hz
)
Note!
ƒ
4−pole asynchronous motors which are designed for a rated frequency of
50 Hz in star connection can be operated in delta connection up to 87 Hz
when being constantly excited.
– The motor current and the motor power are then increased by the factor
Ö3 = 1.73.
– The field−weakening range starts above 87 Hz.
ƒ
Advantages:
– Higher speed−setting range
– 73 % higher power efficiency with standard motors.
ƒ
Basically, this procedure can also be used for motors with other numbers of
poles.
– Observe mechanical limit speeds in case of two−pole asynchronous
motors.